Korean J Anesthesiol Search

CLOSE


Previous issues

  • HOME
  • BROWSE ARTICLES
  • Previous issue
Volume 33(5); Nov 1997
Experimental Research Articles
The Effects of Ketamine on Hemodynamics and Intracranial Pressure during O2-N2O-Isoflurane Anesthesia in Rabbits.
Young Kyoo Choi, Sun Ae Moon, Keon Sik Kim, Dong Ok Kim, Doo Ik Lee
Korean J Anesthesiol. 1997;33(5):804-810.
BACKGROUND
The potential adverse effects of ketamine in neurosurgical anesthesia have been well established. However, the effects of ketamine on intracranial pressure (ICP) and hemodynamics during general anesthesia remain unclear. The purpose of this study was to assess the effects of ketamine on hemodynamics and ICP in anesthetized, ventilated rabbits.
METHODS
Thirty rabbits were divided into three groups: Group 1 (n=10) received 1 ml/kg normal saline iv; Group 2 (n=10) received 0.5 mg/kg ketamine iv; Group 3 (n=10) received 1.0 mg/kg ketamine iv. After induction with thiopental, anesthesia was maintained with isoflurane and nitrous oxide in oxygen. During controlled ventilation, ICP, mean arterial pressure (MAP), cerebral perfusion pressure (CPP) and heart rate (HR) were measured. The ICP was measured using Ladd ICP monitoring system. All variables were evaluated at baseline and for 30 min following ketamine.
RESULTS
In group 1, ICP, MAP, CPP and HR were unchanged over the course of the study. In group 2, ICP, MAP and CPP were unchanged. HR increased at 1, 3 and 5 min (p<0.01), 10 and 20 min (p<0.05) after injection. In group 3, ICP, MAP and CPP increased at 1 and 3 min (p<0.01) after injection. HR increased at 1, 3 and 10 min (p<0.01), 5 min (p<0.05) after injection.
CONCLUSIONS
These results suggest that 0.5 and 1.0 mg/kg of ketamine don't significantly affect the hemodynamics and ICP in anesthetized, mechanically ventilated rabbits.
The Pulmonary Hemodynamic Effects of Nitric Oxide Inhalation on Hypoxic Pulmonary Vasoconstriction.
Hae Jeong Jeong, Seong Kee Kim, Chung Su Kim, Jeon Jin Lee, Sung Deok Kim
Korean J Anesthesiol. 1997;33(5):811-821.
BACKGROUND
Nitric Oxide (NO) has been discovered to be an important endothelium-derived relaxing factor. The exogenous inhaled NO may diffuse from the alveoli to pulmonary vascular smooth muscle and produce pulmonary vasodilation, but any NO that diffuses into blood will be inactivated before it can produce systemic effects. To examine the effects of NO on pulmonary and systemic hemodynamics, NO was inhaled by experimental dogs in an attempt to reduce the increase in pulmonary artery pressure (PAP) and pulmonary vascular resistance (PVR) induced by hypoxia in dogs.
METHODS
Eight mongrel dogs were studied while inhaling 1)50% O2 (baseline), 2)12% O2 in N2 (hypoxia), 3)followed by the same hypoxic gas mixture of O2 and N2 containing 20, 40 and 80 ppm of NO, respectively.
RESULTS
Breathing at FIO2 0.12 nearly doubled the pulmonary vascular resistance from 173 56dyn sec cm-5 to 407 139dyn sec cm-5 and significantly increased the mean pulmonary artery pressure from 16 3mmHg to 22 4mmHg. After adding 20~80 ppm NO to the inspired gas while maintaining the FIO2 at 0.12, the mean pulmonary artery pressure decreased (p<0.05) to the level when breathing oxygen at FIO2 0.5 while the PaO2 and PaCO2 were unchanged. The pulmonary vascular resistance decreased significantly and the right ventricular stroke work index returned to a level similar to breathing at FIO2 0.5 by addition of NO into the breathing circuit. Pulmonary hypertension resumed within 3~5 minutes of ceasing NO inhalation. In none of our studies did inhaling NO produce systemic hypotension and elevate methemoglobin levels.
CONCLUSIONS
Inhalation of 20~80 ppm NO selectively induced pulmonary vasodilation and reversed hypoxic pulmonary vasoconstriction without causing systemic vasodilation and bronchodilation. Methemoglobin and NO2 were within normal limit during the study.
Clinical Research Articles
Midazolam Pharmacokinetics in Patients Undergoing Lung Surgery.
Soo Il Lee, Seung Su Kim, Gi Baeg Hwang, Jong Hwan Lee
Korean J Anesthesiol. 1997;33(5):822-828.
BACKGROUND
The nature of operation alters the volume of distribution at steady state (Vdss) of drug. The hepatic extraction ratio of midazolam (0.3~0.7) could be influenced by hepatic blood flow (HBF), and hepatic enzyme activity. The pharmacokinetics of intravenous midazolam were determined in patients undergoing lung surgery.
METHODS
Midazolam, 0.2 mg/kg, was administered to five patients undergoing lung surgery at 30 minutes after induction of anesthesia. Anesthesia was maintained with O2-enflurane for one lung ventilation. Blood samples from artery were drawn at increasing intervals for 12 h. Plasma midazolam concentrations were measured by gas chromatography. Computer simulations of the times required for 20%, 50%, and 80% decreases in midazolam concentrations were performed.
RESULTS
A three compartment model best described the concentration versus time data. The volume of the central compartment (Vc) and volume of distribution at steady state (Vdss) were 4.3 2.8 l and 59.9 20.1 l, respectively. The elimination half-life was 3.4 2.2 h. Simulations indicate that under all the situations, the concentrations would decrease more rapidly in our patients in spite of similar Vdss and elimination half-life of patients undergoing minor gynecological surgery.
CONCLUSION
The elimination half-life was in the range of previously reported values. The shorter recovery time is apparently due to relatively faster redistrubution, and relatively greater capacity for redistribution.
Comparison of the Optimal Depth of the Internal Jugular Venous Catheterization between Right and Left.
Sang Hwan Do, Chong Soo Kim, Byeong Geon Lee, Jung Won Hwang, Mi Sook Kwak, Il Yong Kwak
Korean J Anesthesiol. 1997;33(5):829-832.
BACKGROUND
The purpose of this study was to measure and compare the optimum depth of the internal jugular venous catheterization between the right and left side.
METHODS
Forty-four patients were enrolled for this study and divided into two groups (22 patients each). The optimum depth of the catheterization was calculated using the sum of two component (A and B); the advanced length of the catheter from the level of the cricoid cartilage (A) and the distance from the catheter tip to the junction of the superier vena cava and right atrium (B).
RESULT
The optimum depths of the internal jugular venous catheterization were 16.0 1.0 cm (right) and 18.4 1.5 cm (left) respectively. Left side was significantly longer than right side (p<0.05). In this study, we experienced some complications; arterial punctures (5 cases) and migration of the catheter to the opposite subclavian vein (1 case). Five complications were associated with left internal jugular venous cannulation and one was associated with the right side cannulation.
CONCLUSION
We concluded that the optimum depth of the internal jugular venous catheterization was longer in the left side than in the right side.
Displacement of the Endotracheal Tube is not Related to Its Fixation or Unflxation When the Neck is Extended or Flexed.
Young Su Kim, Se Hun Park, Sie Jeong Ryu, Kyung Han Kim, Tae Ho Jang, Se Hwan Kim
Korean J Anesthesiol. 1997;33(5):839-843.
BACKGROUND
Endobroncheal intubation or extubation may occur accidentally when the patient's neck is flexed or extended even in the appropriate endotracheal intubation. The purpose of this study is to examine the effect of fixation or unfixation of the endotracheal tube at the teeth level on the displacement of its distal end when the patient's neck is extended or flexed.
METHODS
This study was conducted in 37 patients who underwent endotracheal general anesthesia. The patients with the evidence of pathology in head, neck and chest were excluded from the study. Individual patient's displacement in endotracheal tube tip compared unfixed cases with fixed cases when the change of neck position. The moved distance was measured by fiberoptic bronchoscope. The data were statistically analyzed by Student's paired t-test.
RESULTS
The endotracheal tube moved away from the carina when the patient's neck was extended, while it moved toward the carina when flexed in all cases. When the patient's neck was extended the average distance displaced 1.2 0.7 cm in fixed cases and 1.1 0.9 cm in unfixed cases. when the neck was flexed, they were 1.2 0.5 cm and 1.0 0.8 cm respectively. There were not statistically significant between the fixed and the unfixed cases.
CONCLUSIONS
It is concluded that the displacement of the endotracheal tube is not related to its fixation or unfixation at the teeth level and therefore, unfixation does not provide any benefits in terms of the displacement of the distal end of the tube in adult trachea.
Appropriate Sizes of Uncuffed Endotracheal Tubes and Distance from Upper Incisor to Carina in Korean Children under Eight Years Old.
Yong Joo Kim, Weon Sik Ahn, Yeong Jin Rho, Jin Ho Bae, Chong Sung Kim, Seong Deok Kim
Korean J Anesthesiol. 1997;33(5):844-848.
BACKGROUNDS
Various methods have been devised for choosing the correct internal diameter (ID) of endotracheal tubes and the proper lengths for oral endotracheal tubes at different ages in children. This study was performed to evaluate the appropriate sizes of uncuffed endotracheal tubes and distance from upper incisor to carina in Korean children under 8 years old.
METHODS
Five hundred thirty five children under 8 years in ASA class 1 and 2 were evaluated for the study by age groups: 0~3 months, 4~11 months and every each year until 8 years. Appropriate sizes were to permit a gas leak at 15~25 cmH2O with positive pressure ventilation. Distances from incisor to carina were at the point which bilateral lung sounds were noticed during slow extubation from endobroncheal intubation.
RESULTS
Appropriate tube sizes were 3.0 mm to 3.5 mm for infants under 3 months, 3.5 mm to 4.0 mm for 4 to 11 months and ""4.15+0.28xage (yr) (mm)"" (R2=0.77, p<0.05) for children between 1 and 8 years old. Distances from upper incisor to carina were 12.0 cm for infants under 3 months, 13.7 cm for 4 to 11 months and ""14.5+0.6xage (yr) (cm)"" (R2=0.62, p<0.05) for children between 1 and 8 years old.
CONCLUSIONS
We conclude that the endotracheal tube ID for the Korean children are a little greater than those of previous reports in foreign countries and airway lengths for the Korean children are similar to those of foreigners.
A Study about the Bronchial Cuff Volume of the Left-sided Double-Lumen Endobronehial Tube.
Mi Kyung Yang, Yong Sang Cho, Gaab Soo Kim, Chung Su Kim, Byung Dal Lee, Baek Hyo Shin
Korean J Anesthesiol. 1997;33(5):849-857.
"Background: In using the Double-lumen tube (DLT), knowing the minimum bronchial cuff volume (MCV) for an effective air-tight seal will be useful; to provide a collapse of the lung; and to avoid pressure damage. The aims of the present study are thus three-fold: to measure the MCV; to measure the diameter of left main bronchus (LMBD); and to prove any relationships between two parameters.
METHODS
One hundred men and forty women who needed intubation of left-sided DLT were enrolled in this study. 37 Fr DLTs were used in male patients, and 35 Fr DLTs were used in female patients. We evaluated the MCV by air bubble method and measured the LMBD in chest PA. We also evaluated the pressure/volume characteristics of the bronchial cuffs by control inflator.
RESULTS
29 patients of 100 patients (29%) exhibited persistent air leakage in 2.5 ml cuff volume in male patients (group of MCV >2.5). On the contrary, 18 patients of 40 patients (45%) did not require any cuff volume in female patients (group of MCV 0). The mean LMBD were 13.23 1.45 mm in male and 11.09 0.96 mm in female. There were significant positive correlations between MCV and LMBD in both sex and their respective correlation coefficients were 0.264 (P=0.008) in male and 0.484 (P=0.002) in female. The equations of linear regression were: LMBD = 12.394 0.429xMCV in male, LMBD = 10.725 0.438xMCV in female.
CONCLUSIONS
The MCV of the brochial cuffs in left-sided DLTs has significant relationships with the LMBD measured in chest PA.
Arterial Blood Pressure and Heart Rate Response to Lightwand or Direct Laryngoscopy for Endotracheal Intubation.
Yong Seok Oh, Sung Hee Han, Yoon Suk Lee, Jin Huh
Korean J Anesthesiol. 1997;33(5):858-863.
BACKGROUND
Tracheal intubation commonly results in sympathetic stimulation manifested by increased heart rate and arterial blood pressure. This study was carried out to determine whether lightwand would result in less hemodynamic changes than direct laryngoscopy.
METHODS
With informed consent, fourty healthy female patients scheduled of elective surgical procedures were randomly allocated into two groups; lightwand (LW) or direct laryngoscopy (DL) group. Mean arterial pressure (MAP) and heart rate (HR) were recorded upon arrival. Under a standardized anesthetic technique, the patients were intubated either with no. 3 curved blade direct laryngoscopy (DL group) or with lightwand (LW group). The MAP and HR were recorded before intubation and every 1 minutes following intubaion. Time to intubation (TTI) was also recorded. All patients were intubated by a same fourth grade resident.
RESULTS
Fourty patients were studied. Every intubation was successed in first attempt. The TTI was significantly shorter in LW group. Even while there was no significant difference in HR changes, there was significant difference in the increase of MAP following intubation. The increase of MAP was significantly greater with DL than with LW.
CONCLUSIONS
This study suggests that lightwand intubation requires shorter TTI and may give rise to less blood pressure change than direct laryngoscopy. So we found no difference in disadvantage and may offers advantage in terms of hemodynamic stability.
The Effect of Endotracheal Tube Cuff Filled with Lidocaine and Sodium Bicarbonate Mixture on Postoperative Sore Throat and Hoarseness Following General Endotracheal Anesthesia.
Bo Ryoung Lee, Soo Won Oh, Dong Hyun Kim, Gil Hoi Koo
Korean J Anesthesiol. 1997;33(5):864-867.
BACKGROUND
Postintubational sore throat and hoarseness are usually mild symptoms but they are very common complaints among the patients after endotracheal general anesthesia. In addition, some might have severe discomfort and need invasive procedure to relieve these problems. We tried new method of endotracheal tube cuff filling with local anesthetics to reduce postoperative sore throat and hoarseness and evaluated the results.
METHODS
Endotracheal cuff filling was done with air 5 ml in healthy 20 patients (ASA I-II, control group). And in another healthy (ASA I-II) 35 patients, the cuffs were filled with 4% lidocaine 3.5 ml and 8.4% sodium bicarbonate 1.5 ml mixture. After 24 hours following general anesthesia, patients were visited and asked whether there were sore throat or hoarseness, if any, how the degree was.
RESULTS
In lidocaine-treated group, the incidence of postintubational sore throat was less compared to control group significantly. There was no difference in incidence of hoarseness between two groups.
CONCLUSION
Endotracheal cuff filled with lidocaine and sodium bicarbonate mixture is suggested as an effective protective method that reduces the frequency of postintubational sore throat.
Comparison of Intubation Following Propofol-Fentanyl with Intubation Following Succinylcholine-Thiopental Sodium.
Boung Yong Park, Yiel Moon Kim, Hae Ja Kim, Won Hyung Lee, Yong Sup Shin, See Jin Choi
Korean J Anesthesiol. 1997;33(5):868-875.
BACKGROUND
This study was performed to determine the effect of a endotracheal intubation & induction of anesthesia using propofol 2.0 mg/kg or 2.5 mg/kg and fentanyl 2 g/kg without succinylcholine chloride. Also we have compared this method with technique using succinylcholine 1.5 mg/kg and thiopental sodium 5 mg/kg.
METHODS
They were divided into 3 groups as follows: group 1, succinylcholine 1~1.5 mg/kg and thiopental sodium 5 mg/kg; group 2, propofol 2 mg/kg and fentanyl 2 microgram/kg; group 3, propofol 2.5 mg/kg and fentanyl 2 microgram/kg. Systolic arterial pressure (SAP) and diastolic arterial pressure (DAP), and heart rate (HR) were measured before induction, after induction, after tracheal intubation immediately, at 1, 2, 3, and 5min. after tracheal intubation in all patients. The incidence of adverse effects and the quality of condition for intubation were measured in all patients.
RESULTS
There were significant increases in SAP, DAP, HR after intubation in group 1 but significant decreases in SAP, DAP after induction and at 5min. after intubation in group 2 and group 3. The incidence of adverse effects, and the quality of condition for intubation were no significant difference between group 1 and group 3.
CONCLUSIONS
From the above result, use of propofol 2.5 mg/kg and fentanyl 2microgram/kg provided a satisfactory alternative to succinylcholine and thiopental sodium for rapid sequence induction of anesthesia.
The Effect of Hyperventilation on Serum Potassium Concentration During Infusion of Mannitol.
Kyu Sam Hwang, Joung Uk Kim, Jong Ho Choi, So Young Lee, Eun Ju Lee, Sung Min Han
Korean J Anesthesiol. 1997;33(5):876-882.
BACKGROUND
Mannitol is widely used in neurosurgical patients and may induce an increase in serum potassium concentration according to doses and administration rates with unknown mechanism. The treatment of hyperkalemia is aimed at eliminating the causes and includes calcium, sodium bicarbonate, glucose with insulin, loop diuretics and hyperventilation. This study was undertaken to observe the effects of hyperventilation on the serum potassium concentration following infusion of mannitol (2.0 gm/kg).
METHODS
We studied 30 patients who were operated brain aneurysm clipping surgery and were divided into 3 groups (n=10). In control group, mild hypocapnia was maintained (PaCO2, 32 2 mmHg) before and after mannitol infusion. In group I, moderate hypocapnia was maintained (PaCO2, 27 2 mmHg) before and after mannitol infusion. In group II, mild hypocapnia (PaCO2, 32 2 mmHg) was maintained before 30 minutes of mannitol infusion and moderate hypocapnia (PaCO2, 27 2 mHg) after mannitol infusion. We started infusion of 20% mannitol with a dosage of 2.0 gm/kg, 15~20 min after cranium was opened.
RESULTS
The changes of serum potassium were as follows (Mean SD mEq/l) (just before and 15min, 30min, 60min after mannitol infusion): 3.79 0.48, 4.66 0.60, 4.44 0.48, 4.13 0.40 (Control group), 3.62 0.18, 3.63 0.42, 4.14 0.51, 3.95 0.33 (Group I), 3.76 0.20, 3.91 0.15, 4.11 0.30, 4.04 0.23 (Group II). After 15 minutes of mannitol infusion, the serum potassium levels of group I and II were lower than that of control group (p<0.05) and there was no significant difference between group I and II.
CONCLUSIONS
These results suggest that hyperventilation may blunt the increase in serum potassium concentration following rapid infusion of high dose mannitol.
The Effects of Doxapram on the Pulmonary Function during Total Intravenous Anesthesia with Propofol According to Nalbuphine Pretreatment.
Sang Wook Shin, Dong Hee Kang, Seung Wan Baik
Korean J Anesthesiol. 1997;33(5):883-889.
BACKGROUND
Total intravenous anesthesia with propofol can cause respiratory depression and apnea especially during induction of anesthesia. To study the possibility of reversal of respiratory depression during anesthesia with propofol, pretreated with nabuphine or not, the respiratory effects of doxapram to spontaneously ventilating patients were investigated.
METHODS
Patients were divided into 4 groups - saline-propofol-saline group (SPS), saline-propofol- doxapram group (SPD), nalbuphine-propofol-saline group (NPS), and nalbuphine-propofol-doxapram group (NPD). After saline or nalbuphine pretreatment, anesthesia was induced with propofol and then doxapram or saline was intravenously injected. Apneic time interval, blood pressure, heart rate, respiratory rate, minute ventilation, end tidal CO2 partial pressure and oxygen saturation were measured in every minutes during induction of anesthesia. Percent changes of each values were compared.
RESULTS
There is no differences in apneic time intervals in each groups. The percent change of first minute ventilation in SPD group after doxapram injection unchanged significantly compared with those depressions of SPS, NPS and NPD group (p<0.05). Respiratory rates increased in SPD and SPS groups after laryngeal mask insertion. There is no differences in minute ventilation, respiratory rate and end-tidal CO2 concentration between nalbuphine pretreated groups regardless of doxapram injection.
CONCLUSIONS
Doxapram has effect in increasing minute ventilation after propofol induction within first few minutes, but it cannot reverse respiratory depression during propofol induction pretreated with nalbuphine.
Clinical Usefulness of Isoconcentration Nomogram for Continuous Infusion of Fentanyl in Propofol-Fentanyl Total Intravenous Anesthesia (TIVA).
Ho Yeong Kil, Tae Kyoun Kim, Seung Joon Lee, Young Joon Yoon
Korean J Anesthesiol. 1997;33(5):890-895.
BACKGROUND
To estimate real time concentration of drugs during TIVA is theoretical, but it is not easy and inefficient. To maintain designed target concentration with continuous infusion using methods that account for the multicompartmental pharmacokinetic profile of fentanyl, isoconcentration nomogram is one of the methods. We evaluated the clinical usefulness of the isoconcentration nomogram using two different expected concentration of fentanyl.
METHODS
Thirty ASA class I or II adult patients scheduled for spine fusion were randomly allocated into two groups according to 1.5 or 3 ng/ml of expected fentanyl concentration. Using isoconcentration nomogram, fentanyl concentration was adjusted and the propofol concentration was fixed to 3.5 g/ml according to Prys-Roberts method. Vital signs were titrated using variable flow rate of propofol. Fentanyl and propofol were discontinued 15 min before the end of operation. And, IV-PCA using fentanyl were applicated for postoperative pain control. The dosage of propofol and fentanyl, recovery time of consciousness and orientation were checked. Also, first buttoning time and 24hr fentanyl dosage in IV-PCA were checked.
RESULTS
Average flow rate of propofol used were 7.5 1.2 mg/kg/hr in group 1, 5.7 1.1 mg/kg/hr in group 2 which was significantly lower than group 1 (p<0.05). Spontaneous eye opening and recovery of orientation was delayed 1.8 times in group 2. First buttoning time and 24hr fentanyl requirement for postoperative pain control using IV-PCA was delayed by 2 and decreased 60% in group 2, respectively.
CONCLUSIONS
Isoconcentration nomogram was useful tool to control the expected concentration of fentanyl during TIVA and postoperative pain control using fentanyl IV-PCA.
Changes of Blood Glucose and Insulin under Different Fentanyl Dosage in Neonates and Infants Undergoing Open Heart Surgery.
Young Jhoon Chin, Chung Yoo Lee, Jong Guk Lee, Han Suk Park
Korean J Anesthesiol. 1997;33(5):896-902.
Background
Hyperglycemia during cardiopulmonary bypass may increase the incidence and severity of neurologic deficits that may result from cerebral ischemia. Moderate hyperglycemia has been noted to occur in pediatric patients undergoing cardiac surgery despite measures such as eliminating dextrose from the CPB clear pump priming solution and from the intra-operative iv fluids. To ameliorate the hormonal and hemodynamic stress responses during cardiac surgery in neonates, infants and children, high dose fentanyl anesthesia is widely used. The authors wished to determine prospectively whether fentanyl dosage is associated with reduced blood glucose or not in pediatric patients undergoing cardiac surgery.
METHODS
Twenty four pediatric patients undergoing cardiac surgery were allocated randomly into 3 groups who received 25 g/kg fentanyl, 50 g/kg fentanyl or 75 g/kg fentanyl before CPB. The changes of plasma glucose and insulin levels were observed after sternotomy, on bypass, 30 min after bypass, off bypass, and the end of the operation.
RESULTS
Blood glucose levels were not increased after sternotomy, but significantly increased at bypass to the end of the operation in all fentanyl dosage groups. Plasma insulin level increased, but statistically not significant. Different fentanyl dosage (25~75 g/kg) is not associated with differences in blood glucose level.
CONCLUSION
At a dosage of 25~75 g/kg fentanyl anesthesia during pediatric open heart surgery were associated with no differences and below 250 mg/dl of blood glucose level and no significant changes in insulin level.
Clinical Anaylsis of Anesthetic Dosage and Use of Ephedrine in Epidural Anesthesia for Cesarean Section.
Hye Ryung Chung, Tae Hwan Kim, You Hung Won
Korean J Anesthesiol. 1997;33(5):903-907.
BACKGROUND
Hypotension occurs frequently after epidural anesthesia. Intravenous fluid or vasopressors are among treatment methods to many suggested causes. This study was undertaken retrospectively to determine if the age, weight and height of parturients are related to the local anesthetic dosage in epidural anesthesia for the cesarean section, and if the dosage of local anesthetic influence the change of blood pressure and the requirement of fluid or epherine.
METHODS
Sixty-nine parturients were studied by reviewing patients' anesthetic records. During lumbar epidural anesthesia to T4 sensory level, all patients were monitored with mean arterial blood pressure, and prevented from hypotension by administration of Ringer's lactated solution. But if hypotension has been sustained in spite of rapid fluid loading, intermittent ephedrine was injected. We studied the correlation of local anesthetic dosage, decrement of mean blood pressure and total required intravenous fluid volume, and difference of these variables between cases using ephedrine and not using.
RESULTS
The volume of local anesthetic to achieve a T4 sensory level was 21.20 3.81ml, which did not correlate with age, weight and height, and did not influence the decrease of mean blood pressure and the volume of administered fluid. But the patients (n=30) who needed ephedrine were adminstered significantly larger dose of the local anesthetic and showed more decrease in the mean blood pressure than those (n=39) who did not.
CONCLUSIONS
The dose requirement of local anesthetic during epidural anesthesia for the cesarean section is not determined by the age, weight and height of parturients. But when larger dose of local anesthetic is administered, the patients seem to be more hypotensive and need ephedrine as well as intravenous fluid administration.
Effect of Loss of Epidural Negative Pressure on Spinal Sensory Blokade Level of Spinal Anesthesia.
Bong Il Kim, Woon Seok Rho, Kun Hee Lee
Korean J Anesthesiol. 1997;33(5):908-911.
BACKGROUND
We postulated that loss of epidural negative pressure might affect on the sensory blockade level of spinal anesthesia.
METHODS
Thirty nine patients were involved in our study; group 1, spinal anesthsia with 23G spinal needle (n=20): group 2, spinal anesthesia with 27G spinal needle through the 18G Weiss epidural needle (n=19). Sensory blockade level was checked by pinprick test at 5, 10, 15, 20, 25, 30, 40, 60 and 90 minutes after spinal anesthesia.
RESULTS
There was no difference of sensory blockade level between group 1 and 2.
CONCLUSION
From above result, there was no evidence of loss of epidural negative pressure affecting on the spinal sensory blockade level.
Augmentin-Induced Coagulation Abnormalities as Measured by Thromboelastography.
Sung Geun Yoon, Eun Mi Kim, Myoung Hye Park, Ho Sung Kwak
Korean J Anesthesiol. 1997;33(5):912-917.
BACKGROUND
Antibiotics are used prophylactically in surgery to prevent postoperative infection. However, antibiotics administered in large doses can cause a bleeding diathesis as a result of platelet dysfunction. We wondered whether these antibiotics might impair platelet function by interfering with the initial step of platelet activation: the binding of agonists to their specific receptors on the platelet surface.
METHODS
In 30 patients (male 18, women 12) undergoing primary elective knee arthroscopic surgery, the whole blood coagulation system was prospectively evaluated before, and 10 and 40 minutes after administration of 1 g of augmentin. All patients who had abnormal preoperative coagulation profiles or who received anticoagulant or antiplatelet, antibiotics therapy within 7 days prior to surgery were precluded.
RESULTS
At 10 minutes after augmentin administration 25 of 30 patients had a significant impairment in all phases of whole blood coagulation as monitored by thromboelastography. In contrast, three of 30 patients had a significantly decreased coagulation time. Two of 30 patients had no significant changes of TEG variables. TEG variables were restored toward baseline in fourty minutes after augmentin administration.
CONCLUSIONS
Augmentin can cause a significant but transient change in the viscoelastic properties of blood. Coagulation parameters of the TEG should be measured prior to augmentin administration to prevent and prospect a bleeding diathesis as a result of platelet dysfunction.
Coagulation Status Changes during Progressive Hemodilution.
Young Soon Choi, Woo Jae Joun, Gaab Soo Kim, Tae Soo Hahm, Chung Su Kim, Baek Hyo Shin
Korean J Anesthesiol. 1997;33(5):918-922.
BACKGROUND
Hemodilution reduces the concentration of clotting factors in blood and this may induce some degree of impairment of coagulation. But there are some evidence that hemodilution may induce a hypercoagulable state. The goal of this study is to investigate the changes of coagulation status during progressive hemodilution.
METHODS
Whole Blood was diluted by 10% increment to 80% with 0.9% normal saline. At each 10% dilution blood coagulation status was analysed using thrombelastography (TEG) and was compared with that of an undiluted control specimen obtained concurrently from the same patients.
RESULTS
Hemodilutions up to 40% decrease r and K times and increase values of MA and angle. Hemodilutions more than 70% increase r and K times and decrease values of MA and angle.
CONCLUSIONS
Hemodilutions up to 40% increase coagulability and hemodilutions more than 70% decrease coagulability of whole blood in vitro.
In Moderate Anemic Patients with Normal Cardiopulmonary Function, Should Preoperative Blood Transfusion be a Mandatory Procedure in Uterine Myoma Patients.
Kyu Jong Lee, Sang Gon Lee, Jong Il Kim, Jong Seouk Ban, Byung Woo Min
Korean J Anesthesiol. 1997;33(5):923-927.
BACKGROUND
In anemic patients, it has been usually traditional practice to correct the anemic state with preoperative blood transfusion. But now, there is an increasing tendency of refusing blood transfusion due to the transfusional complications, especially AIDS etc. The purpose of this study is to survey the effects of anesthesia in anemic patients with normal cardiopulmonary function compared to non-anemics.
METHOD
40 patients with uterine myoma were divided into two groups, an experimental group of 20 patients with hemoglobin concentration of 8~10 gm% and a control group of 20 patients with hemoglobin concentration higher than 10 gm%, and their blood pressure, pulse rate and arterial oxygen saturation were monitored and compared.
RESULTS
There were no significant differences between two groups in blood pressure, pulse rate and arterial oxygen saturation.
CONCLUSION
Preoperative blood transfusion, in patients with moderate anemia, does not seem to be a mandatory practice.
Comparison of Hemodynamic Effects between Dobutamine and Amrinone in the Patients with Pulmonary Hypertension.
Yong Woo Hong, Young Lan Kwak, Sang Kee Min, Sang Beom Nam, Seo Ouk Bang, Eun Sook Yoo, Myoung Ouk Kim, Min Seok Kim
Korean J Anesthesiol. 1997;33(5):928-936.
BACKGROUND
Dobutamine and amrinone, phosphodiesterase-III inhibitor, are known to have both inotropic and vasodilatory properties. We evaluated the effects of both drugs on systemic and pulmonary hemodynamics in patients with pulmonary hypertension (PH).
METHODS
With Institutional Review Board approval, 45 patients whose mean pulmonary arterial pressure was greater than 30 mmHg were studied. After sternotomy under the steady state of anesthesia and controlled ventilation (30 mmHg < PaCO2 < 40 mmHg), patients recieved one of following drugs for 30minutes (min); dobutamine 5.0ug/kg/min (Group I), low dose amrinone (loading dose 1.0 mg/kg, followed by infusion 7.5 g/kg/min, Group II) or high dose amrinone (loading dose 2.0 mg/kg, followed by infusion 10 g/kg/min, Group III). Hemodynamic variables were measured at 10 min and 30 min after start of infusion.
RESULTS
Dobutamine didn't decrease pulmonary arterial pressure (PAP) and cause no hemodynamic change while low and high dose amrinone reduced PAP and especcially decrease of PAP in low dose amrinone group was statistically significnat. High dose amrinone increased cardiac index (CI) and decreased both systemic vascular resistance index (SVRI) and central venous pressure (CVP) more significantly than control value.
CONCLUSIONS
In patients with chronic right ventricular failure associated with PH, amrinone may decrease the PAP and improve cardiac performance more effectively than dobutamin does. Increment of dosage of amrinone may not result in significant reduction of PAP.
Efficacy of Patient-Controlled Epidural Analgesia according to Changes of Continuous Background Infusion Volume.
Dong Hee Kim, Choong Hak Park, Sook Lee
Korean J Anesthesiol. 1997;33(5):937-943.
BACKGROUND
This study examined the efficacy of patient-controlled epidural analgesia (PCEA) for post-cesarean section pain control and compared the suitability of four different volumes of continuous background infusion (CBI).
METHODS
Sixty patients were received 0.125% bupivacaine with 5 g/ml fentanyl by PCEA (2 ml of demand dose and 10 minutes of lockout interval) and CBI. Experimental groups were divided four groups according to the volumes of CBI; 1 ml/hr, 2 ml.hr, 3 ml/hr and 4 ml/hr of CBI during 48 hours postoperatively.
RESULTS
Total amount of fentanyl and bupivacaine consumption was significantly higher in 1ml/hr of CBI group than 2 ml/hr of CBI group during first 24 hours, and in 4 ml/hr of CBI group than 1 ml/hr and 3 ml/hr of CBI group during second 24 hours. CBI/maximum hourly demand dose was 15~23%. There is no significant difference between the groups in pain score, side effects and patient's satisfaction.
CONCLUSIONS
This study suggests that two or three ml/hr of CBI can provide the most effective postoperative analgesia and the optimal ratio of CBI/maximum hourly demand dose is about 20%.
Clinical Analysis of 200 Renal Transplantations.
Kyeng Ha Ryu, Young Saeng Kim, Seong Doo Cho, Nam Weon Song
Korean J Anesthesiol. 1997;33(5):944-952.
BACKGROUND
Since the initial report on anesthesia for the renal transplantation from Peter Bent Brighan Hospital in 1962, the anesthesia for kidney transplantation has been reviewed and discussed by many authors. We have performed 200 renal transplantations from August 1990 to October 1996. No cadaveric donor was used and all except two cases was the first graft.
METHODS
Anesthetic procedures in the recipients were as follows; 1) The recipient was dialysed within 24 hrs prior to operation. 2) Premedication was done as glycopyrrolate and fentanyl, or glycopyrrolate and diazepam. 3) Thiopental and vecuronium, or thiopental and succinylcholine were used for anesthetic induction. 4) N2O-O2-relaxant (vecuronium) with halothane or isoflurane were used for maintenance. 5) Neostigmine or pyridostigmine were also used to antagonize against the relaxant. 6) CVP was maintained around 10~17 cmH2O.
RESULTS
The results were as follows; 1) The mean ages of donors and recipients were 35.3 and 37.4, respectively. The ratio of male to female of donors and recipients was 1.6 : 1 and 1.6 : 1, respectively. 2) One hundred and ten cases (55.0%) were living unrelated donors and 90 cases (45.0%) were living related donors. 3) Overall graft and patient survival rate was 96.9 and 98.0 at 1 year, 94.1 and 95.1 at 3 years.
CONCLUSIONS
Most patients with renal failure have several common problems that are of significance to anesthesiologists, including anemia, bleeding tendency, electrolyte imbalance, acidosis, hypertension, hyper- or hypovolemia, and previous therapy with steroids and immunosuppressants, etc. Therefore anesthesiologists should keep in mind the risk factors above mentioned for the anesthetic management of patients with renal failure.
Case Reports
The Use of Transesophageal Echocardiography for Pulmonary Artery Catheter Placement: Two cases.
Byung Ho Lee, Jun Seok Chea, Chang Jae Kim, Mee Young Chung, Seon Heu Seo
Korean J Anesthesiol. 1997;33(5):953-956.
The transesophageal echocardiography (TEE) has been used for the assessment of right and left ventricular function, valvular structure and function, regional wall motion abnormalities and localization of intravascular catheters, cannular and prosthesis. We inserted the pulmonary artery catheter (PAC) under the guidance of intraoperative TEE because of the difficulty of placing PAC with the pressure tracing method in two patients. The PAC was inserted from right atrium to right ventricle with the basal four chamber view and advanced to pulmonary artery through pulmonary valve with the longitudinal view of TEE. We observed typical pulmonary arterial wave form to confirm the correct position. We suggest that the TEE can be used for successful placement of a PAC to facilitate manipulation of the catheter as an alternative method in the patients whose PAC can not be positioned with the pressure tracing method.
The Mechanism of Blood Flow Generation during Closed Chest Cardiac Massage: Transesophageal Echocardiographic Monitoring.
Young Hi Lee, In Chul Choi, Myung Won Cho
Korean J Anesthesiol. 1997;33(5):957-961.
The mechanism of forward blood flow during closed chest cardiac massage remains controversial. Two theories have been suggested: the cardiac pump theory and the thoracic pump theory. Case report is presented to illustrate the use of transesophageal echocardiography during cardiopulmonary resuscitation. The findings included right and left ventricular compression, closure of the mitral valve during compression, opening of the mitral valve during the release phase, and atrioventricular regurgitation during compression, indicating a positive ventricular-to-atrial pressure gradient. These findings suggest that direct cardiac compression was the predominant mechanism of forward blood flow during cardiopulmonary resuscitation in this patient. Transesophageal echocardiography offers a new approach for study of the flows and cardiac morphologic features during chest compressions in humans. An understanding of the actual mechanisms involved is necessary if improved cardiopulmonary resuscitative techniques are to be rationally developed for enhancing the outcome of resuscitation.
Cerebral Oxygen Saturation Monitoring during Aortic Dissection Surgery: A case report.
Chang Gi Kim, Jung Won Hwang, Byung Moon Ham
Korean J Anesthesiol. 1997;33(5):962-966.
Transcranial cerebral oximetry has been successfully used in a variety of neurosurgical conditions, primarily those associated with disturbed cerebral circulation. It has been also used in intraoperative monitoring of aortic dissection and surgical procedures performed under deep hypothermia and circulatory arrest. During disending aortic arch exposure, sudden cerebral oxygen saturation change from 63% to 48% was detected. After therapeutic bypass, cerebral oxygen saturation was increased to 65%. During aortic arch repair, deep hypothermic circulatory arrest with retrograde cerebral perfusion was applied for 130 min and cerebral oxygen saturation slowly decreased from 65% to 52%. Patient was discharged from hospital without neurologic complication and cognitive funtion disturbance.
Cardiac Asystole Following a Single Dose of Succinylcholine: A case report.
Hyun Kyo Lim, Kwang Ho Lee, Hee Uk Kwon, Hyun Kyung Lim
Korean J Anesthesiol. 1997;33(5):967-069.
A 28-yr-old woman, weighing 61 kg with bleeding myoma of uterus was scheduled for total abdominal hysterectomy. There was no history of cardiac arrhythmia or syncope. She was not premedicated. The heart rate was 115 beats/min and arterial pressure was 155/95 mmHg, immediately before the induction of anesthesia. Under the preoxygenation, anesthesia was induced with IV injection of thiopental sodium 250 mg followed by succinylcholine 75 mg. About 20 seconds after the succinylcholine bolus, the ECG showed an abrupt change from sinus rhythm to asystole without any stimulus including laryngoscopy. After a precordial thump and atropine 0.5 mg IV, tracheal intubation and ventilation with 100% O2 were quickly accomplished. Normal sinus rhythm with heart rate of 87 beats/min returned during laryngoscopy and intubation. The interval from the sinus arrest to the reestablishment of normal sinus rhythm was only 15 seconds. Surgery proceeded uneventfully and the patient recovered without any complication.
Three Cases of Taylor's Approach in Geriatric Patients.
Yu Taeg Lim, Young Il Jeong, Dong Chun Ha, Byoung Youn Jeoung
Korean J Anesthesiol. 1997;33(5):970-973.
The Taylor's approach is a special paramedian approach to enter the L5-S1 interspace. The L5-S1 interspace is the largest in vertebral column. This approach is particularly useful when the interspace has been narrowed by pathologic bone destruction such as rheumatoid arthritis or osteoarthritis. Surgery in geriatric patients is associated with a markedly higher incidence of perioperative complication or mortality rate. Optimal anesthetic management of geriatric patients depends on understanding of the normal anatomy and physiologic changes in response to drug in aging. We studied of 3-geriatric patients with Taylor's approach. These patients had problems with respiratory dysfunction and anatomic constraints, which make other approaches unfeasible.
Transient Myocardial Ischemia during General Anesthesia with Isoflurane: Case report.
Hyo Jung Kim, Kyung Hee Park, Hwan Young Choi, Jhong Young Jhun
Korean J Anesthesiol. 1997;33(5):974-978.
Myocardial ischemia occurs when myocardial oxygen availability is inadequate to meet metabolic requirements. The common cause of myocardial ischemia is atherosclerotic epicardial coronary arteries. Isoflurane is a potent small vessel-type coronary vasodilator and has the potential for causing regional myocardial ischemia in patients with coronary disease, but it's still controversial. We experienced a case of transient myocardial ischemia during general anesthesia with isoflurane. The patient was a 51 year- old male who underwent a direct clipping of an anterior communicating artery aneurysm. There was no specific abnormality on preoperative laboratory tests except for mild mitral valve regurgitation on the cardiac echocardiogram. He had once experienced several minutes of sudden severe chest tightness just 3 months before admission, but it had subsided without any specific treatment. One hour after beginning of operation, abnormal EKG changes such as ST-T elevation, QRS widening, VPC, ventricular tachytcardia and ST-T depression appeared and then normalized within 2 minutes with stopping isoflurane and using isosorbide dinitrate. He discharged 12 days later without complications. After discharge, Tread-mill test, SPECT and 2D echocardiogram were performed but there was no any evidence of coronary artery disease.
Acquired Tracheoesophageal Fistula Observed during Anesthetic Induction: A case report.
Chong Soo Kim, Young Jin Lim, Chung Su Kim, Sang Hwan Do, Chang Gi Kim
Korean J Anesthesiol. 1997;33(5):984-987.
We present a case of acquired tracheoesophageal fistula (TEF) which was found during induction of general anesthesia for clipping of aneurysm. The patient had been intubated with endotracheal tube for 10 days and then done tracheotomy for 45 days. Thereafter, TEF was confirmed by MRI and treated with fistula repair and tracheal fenestration. Acquired TEF can occur under the condition of prolonged tracheal intubation with high cuff pressure (>30 mmHg) and can also result from intratracheal neoplasm, mediastinitis, and other tracheal or esophageal damages. If unrecognized during anesthetic induction, TEF can cause gastric dilatation and rupture, pulmonary aspiration and respiratory failure. So early diagnosis and proper management is very important whenever TEF is suspected during anesthetic induction.
General Anesthesia for Patient with Broncho-gastric Fistula: A case report.
Kyeong Ah Kim, Sang Wook Han, Chang Weon Kim, Il Yeong Jung, Ho Jo Jang
Korean J Anesthesiol. 1997;33(5):988-992.
Broncho-gastric fistula caused by benign gastric ulcer perforation after esophagectomy is very rare. In general anesthesia of a patient with broncho-gastric fistula, in spite of hyperventilation, leakage of the anesthetic gases through fistula may make the patient hypercapneic, and positive pressure ventilation may increase the risk of the pulmanary aspiration by the regurgitation of gastric fluid by stomach distension. For that reason, in this patient, denitrogenation was performed during patient's voluntary respiration with 100% oxygen for 5 minutes, and induction was performed without positive pressure ventilation, and one lung ventilation was carried out. Hypoxemia was followed by one lung ventilation because his pulmonary function was moderate obstructive type and his lung was damaged by aspiration of gastric fluid via broncho-gastric fistula. A low level of continuous positive airway pressure (CPAP) has no significant hemodynamic effect and can maintain the patency of nonventilated lung, so hypoxemia induced by one lung ventilation may be reduced. Thus we carried out one lung ventilation with CPAP (10 cmH2O) in nonventilated lung and blocked broncho-gastric fistula with a bronchial blocker for prevention of both regurgitation of gastric fluid and leakage of anesthetic gases. One lung anesthesia was performed without any problem in this case.
A Case Report of Tracheoesophageal Fistula Found during General Anesthesia for Emergency Exploratory Laparotomy.
Kyu Tak Lee, Young Keun Chae, Youn Suk Lee, Choon Kun Chung
Korean J Anesthesiol. 1997;33(5):993-996.
Tracheoesophageal fistula (TEF) occurs in approximately 1 in 3,000 to 5,000 live births. TEF arises from failure of normal division of proximal foregut into separate respiratory and digestive tracts at 4 weeks' gestation. TEF and esophageal atresia are interrelated anomalies, and TEF usually occurs with esophageal atresia. These are usually diagnosed shortly after birth. However, the diagnosis is often delayed in TEF without esophageal atresia, because babies with this anomaly are usually normal in size and seldom have other anomalies. Therefore, sometimes TEF without esophageal atresia is found during operation for an unrelated condition when positive pressure ventilation causes massive inflation of the gastrointestinal tract. We report a case of TEF in adult patient found during general anesthesia for emergency exploratory laparotomy.
Pneumocephalus after Inadvertent Dural Puncture during Epidural Block: A case report.
Byung Hee Lee
Korean J Anesthesiol. 1997;33(5):997-1000.
Pneumocephalus is a rare complication of anesthetic procedures involving the epidural space. With the loss of resistance technique using air, air may be injected in through the dural puncture site. Epidural blood patch was performed for the treatment of post-lumbar puncture headache, and 10 minutes after the treatment, 8 ml of 0.5% bupivacaine hydrochloride was injected through epidural catheter. Loss of consciousness and apnea were developed about 8 minutes after injection of local anesthetics. Computerized tomographic brain scan revealed the presence of air within intracranial cavity. Pneumocephalus may be symptomatic or asymptomatic. It generally responds well to conservative management. The patient did not complain of a headache. The patient was discharged from the hospital on the seventh day postpartum with no neurologic sequelae.


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                
Business Name: Korean Society of Anesthesiologists
Business Registration: 106-82-07194
Representative: Young-Tae Jeon

Copyright © 2026 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next