In a study of obstetric patients requiring intensive care unit (ICU) admission, mechanical ventilation was used in 41% of patients, most often for acute respiratory failure and hemodynamic failure [
1]. Several cases of anesthesia for delivery in women with respiratory failure were reported [
2-
4]. An anesthesiologist should consider the types and drugs of anesthesia, level of regional anesthesia, and support of perioperative ventilatory care. This case report describes the anesthetic course in a pregnant patient with respiratory failure who presented for vaginal delivery and cesarean section. She had severely restricted lung function from tuberculosis-destroyed lung, left pneumonectomy, bronchiectasis on the remnant lung, and superimposed pneumonia. We reviewed anesthetic management of patients with respiratory failure during labor.
Case Report
A 41-year-old woman at 35 weeks' gestation was referred to Department of Anesthesia for analgesia during vaginal delivery. She was 160 cm tall and weighed 57 kg. She suffered from tuberculous pleurisy at 11 years old, diagnosed with tuberculosis-induced destroyed lung at 20 years old, and finally got left pneumonectomy at 25 years old. After the surgery, remnant right lung was bronchiectatic. She had frequent respiratory failure due to respiratory infections and was treated by intermittent admission with mechanical ventilation. At the early period of this admission, due to pneumonia on right lower lobe followed by respiratory failure, she was ventilated mechanically via endotracheal tube. Soon after, she got tracheostomy for prolonged mechanical ventilation. The lowest PaO
2 checked during that period was 36.9 mmHg. It was difficult for her to be weaned from mechanical ventilation after recovery from acute pneumonia, so her ventilation was supported by synchronized intermittent mandatory ventilation (SIMV) or continuous positive airway pressure (CPAP). At 3 months after admission, she was diagnosed as 20 weeks' gestation. The patient elected to continue pregnancy, despite medical warning against influences of prior frequent maternal hypoxemia and heavy medications on fetus, increasingly difficult ventilatory management as she was approaching confinement. She stayed at ICU during rest period of pregnancy with ventilatory support by CPAP. At 35 weeks' gestation, the obstetrician decided to induce delivery, and injected misoprostol 50 µg subcutaneously at 4 hour intervals. Her chest x-ray showed tuberculous scar at right upper lung field, compensatory emphysematous change of whole right lung combined to left pneumonectomy state (
Fig. 1). The last arterial blood gas analysis (ABGA) before onset of labor showed pH 7.362, PaCO
2 49.3 mmHg, PaO
2 241.4 mmHg, HCO
3- 27.7 mmol/L, and 99.8% of oxygen saturation, while the patient was under assisted ventilation with CPAP at FiO
2 0.6. Pulmonary function test was not available. Her hemoglobin value was 10.8 g/dl. The blood chemistry showed hypoalbuminemia (albumin 2.99 g/dl), but other laboratory findings were normal.
We conducted epidural anesthesia with 17-gauge Tuohy needle at L3-4 epidural space by midline approach at lateral position, and inserted a 20-gauge epidural catheter to cephalad. We injected 15 ml of 0.125% bupivacaine and fentanyl 20 µg via epidural catheter. A sensory level to T8 was achieved at 15 min after epidural block. Patient controlled epidural analgesia (PCEA) was applied with initial setting as continuous infusion of 0.125% bupivacaine 5 ml/hr. The bolus injection dose and lockout interval were set to 5 ml and 5 min each, under the control of an anesthesiologist responsible for extending the level of sensory block. Fetal heart rate and uterine contraction were monitored continuously. Because delivery could not be induced by regular injection of misoprostol for two days, elective cesarean section was decided to be performed on the third day from epidural anesthesia. We stopped PCEA and discussed the methods of anesthesia and possible complications with the patient and obstetrician. Both general and epidural anesthesia were easily performed because the patient already had a tracheostomy tube and an epidural catheter. But, the patient strongly refused to be ventilated with control mode ventilation (CMV) under general anesthesia. To be precise, she refused to be paralyzed by neuromuscular blocking agent due to fear of difficult weaning from CMV. The extension of epidural anesthesia up to T4 sensory level through epidural catheter and application of CPAP were planned. On the other hand, we also warned the patient that the level of anesthesia could be incomplete or excessive, and we would have to perform general anesthesia in that situation.
The patient was transported to operative suite with 5 L/min of supplementary oxygen through catheter into the tracheostomy tube. As soon as she arrived at operating room, we connected the anesthetic circuit to tracheostomy tube and applied 8 cmH2O of positive airway pressure with 40% of oxygen in air while the patient breathed spontaneously. The monitoring consisted of electrocardiography, noninvasive blood pressure, arterial oxygen saturation by pulse oximetry (SpO2). Her initial blood pressure was 130/80 mmHg, with heart rate of 75 beats/min and SpO2 97%. After checking patency of the epidural catheter and confirming no bloody aspirates with saline-filled syringe, we injected 15 ml of 2% lidocaine and 50 µg of fentanyl through the epidural catheter. Over the next 10 minutes, additional 10 ml of 1.5% lidocaine was injected epidurally to achieve a level of T4 sensory block to cold. As soon as such a level confirmed, cesarean section was started. A male infant weighing 2.53 kg was delivered within 5 minutes with Apgar scores of 7 and 8 at 1 and 5 min. We injected ephedrine 5 mg intravenously to compensate for hypotension post birth. Total operative duration was 35 minutes and total anesthetic duration was 55 minutes. The result of ABGA after baby birth showed pH of 7.425, PaCO2 40.0 mmHg, PaO2 169 mmHg, HCO3- 27.7 mmol/L, and 99.2% of oxygen saturation. A total 900 ml of Ringer's lactate solution was infused and the patient tolerated well the anesthesia and operation. Blood loss was approximately 500 ml. After completion of cesarean section, we removed the epidural catheter after injection of morphine 3 mg. She was transported to ICU while ventilated mechanically. While in the ICU, her ventilation was assisted with CPAP at the level of pressure support 8 cmH2O with FiO2 0.4. Her vital signs and ventilation parameters were stable. The ABGA showed pH of 7.446, PaCO2 39.7 mmHg, PaO2 32.3 mmHg, HCO3- 27.0 mmol/L, and 98.4% of oxygen saturation. After 2 days, weaning from ventilator was started, but it took 30 days. She was discharged at 77 days after cesarean section with home oxygen supplement.
Discussion
Anesthetic management of pregnant women with respiratory failure poses special problems. The most important problem is reduction in oxygen delivery to the fetus [
5]. Anesthesiologists will try to keep oxygen delivery to the fetus while manage ventilation of mother. The choices of anesthetic methods and drugs require great care.
For the vaginal delivery, we selected an epidural technique with PCEA. Lumbar epidural anesthesia is known to provide pain relief without neonatal respiratory depression or reduced oxygen consumption [
6]. Because the patient with respiratory failure used accessory muscles for respiration, neuraxial anesthesia might disturb the mechanics of breathing, but could provide anesthesia, reduce oxygen consumption, extend duration of analgesia, and expand the range of anesthesia for cesarean section without heavy motor block.
For cesarean section, it should be easy to perform general anesthesia with mechanical ventilation for better control of gas exchange and tracheobronchial toilet, because the patient had tracheostomy tube already. From another perspective, general anesthesia could impair matching of ventilation - perfusion in patients with pulmonary diseases. It could be a reason that anesthesiologists induce regional anesthesia instead of general anesthesia in those patients [
7]. Also, there was a possibility that we might need to change the mode of mechanical ventilation, with a patient who strongly refused to be ventilated by control mode. Since we already placed an epidural catheter, we tried to satisfy the patient's wishes by choosing extension of epidural anesthesia.
To avoid a too extensive block that might impair respiratory function, but to provide adequate anesthesia for cesarean section, we tried to expand epidural anesthesia level to T4. Howell et al. [
8] recommended a maximum block level to T6 for cesarean section in patients with cystic fibrosis to lessen the risks of respiratory embarrassment, but they did not comment which method they used to discern the level of blockade. Cameron and Skinner. [
3] extended the level of anesthesia to T3 by a loss of temperature sensation and T8 by pinprick sensation. The patients tolerated this well, like our patient. Though we used 0.125% bupivacaine for labor analgesia during vaginal delivery, a more potent drug was suitable for epidural anesthesia for cesarean section. Our choice was epidural injection of 2% lidocaine followed by 1.5% lidocaine to reduce total dose, and 50 µg of fentanyl for intense blockade. In previous case reports, other authors used 0.5% bupivacaine, 0.75% ropivacaine, or 1.5-2% lidocaine [
3,
4,
8]. The reason we used lidocaine was to hasten delivery for the needs of the patient and obstetricians who worried about welfare of the baby because of changing fetal heart patterns. In spite of our concern about epidural fentanyl causing respiratory depression, it was not harmful for mother and baby.
Considering that pulmonary sympathetic efferents emerge from the spinal cord between T2 and T7 [
9], our epidural anesthesia might block T4-T7 sympathetic nerves. But, it was known that segmental high thoracic epidural anesthesia alone increases neither airway resistance at rest nor bronchial reactivity to acetylcholine [
10]. Other researchers [
11] have found that segmental high thoracic anesthesia from C4 to T8 or T9 significantly decreased forced expiratory volume at 1 second (FEV
1), but increased forced expiratory volume at 1 second over vital capacity. Consequently, epidural anesthesia producing sympathetic blockade can be used in patients with severe obstructive pulmonary disease. Also, amide local anesthetics absorbed from epidural space attenuated bronchial hyperreactivity dose dependently [
12].
We decided to remove the epidural catheter after cesarean section because three days had passed after placement. Instead of PCEA, we used epidural morphine which the patient tolerated well.
Like prior reports that anesthesiologists used non-invasive positive pressure ventilation for managing the pregnant patients with respiratory failure [
2,
4], we applied CPAP to our patient continuously through tracheostomy tube during cesarean section under epidural anesthesia. We conclude that cesarean section under epidural anesthesia in a patient with respiratory failure is relatively safe when assisted mechanical ventilation is used continuously.