Korean J Anesthesiol Search

CLOSE


Korean Journal of Anesthesiology 2003;45(6):720-726.
DOI: https://doi.org/10.4097/kjae.2003.45.6.720   
Changes of Respiratory Mechanics in Pregnant Woman under General Anesthesia for Cesarean Section.
Ju Yeon Choi, Rack Kyung Chung, Dong Yeon Kim, Jong In Han, Chi Hyo Kim, Guie Yong Lee, Hee Jung Baik, Jong Hak Kim, Yun Jin Kim
Department of Anesthesiology, College of Medicine, Ewha Womans University, Seoul, Korea. rkchung@mm.ewha.ac.kr
Abstract
BACKGROUND
In pregnant woman, the respiratory system is influenced by the hormonal environment and an enlarged gravid uterus. After delivery of the fetus, and contraction of the uterus, changes in the respiratory system produced by the mechanical effect of the gravid uterus may decrease or be reversed. We designed this study to observe changes in the respiratory mechanics in pregnant woman under general anesthesia for cesarean section.
METHODS
15 pregnant women at term, ASA 1 were studied. Induction was performed with thiopental/succinylcholine and maintained with O2, N2O and enflurane until delivery. Just before delivery, enflurane was discontinued. Vecuronium was given at 0.1 mg/kg iv 4 min after induction, and after delivery, 1 mg was given as needed. Inspired tidal volume, expired tidal volume, inspired minute ventilation, expired minute ventilation, airway peak pressure, plateau pressure, expired volume during the first 1 second/expired tidal volume (V1.0), dynamic compliance and end-tidal CO2 were continuously measured just after induction, at delivery and 5, 10, 15, 20, 25, 30, 40 and 50 min after delivery. Blood pressure, heart rate and oxygen saturation were also measured.
RESULTS
Compared to the value after induction, values after delivery showed no significant changes in inspired tidal volume or minute volume, but significantly increased in expired tidal volume and minute volume and dynamic compliance, and a significant decrease in airway peak pressure, plateau pressure, V1.0 and end-tidal CO2. Blood pressure and heart rate increased significantly after induction, compared to before induction. Oxygen saturation was maintained at 99-100%.
CONCLUSIONS
After delivery, the effects of the gravid uterus on the respiratory system rapidly disappeared, in particular changes of pressure in the airway preceded the respiratory volume changes.
Key Words: cesarean section; general anesthesia; respiratory mechanics


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                

Copyright © 2024 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next