BACKGROUND
Clonidine, an alpha2-adrenergic receptor agonist, has been shown to have a sedative effect and to suppress hemodynamics when used as a premedicant. We evaluated the change of AEP index and hemodynamics after clonidine premedication and induction with propofol.
METHODS
The study design was a prospective, randomized, double-blind study. 90 patients who were scheduled for elective surgery were randomly assigned in 3 groups (Group 1, 2 and 3). In groups 2 and 3, the patients were administered 2 microgram/kg or 4 microgram/kg of i.v. clonidine 30 minutes before the induction of propofol anesthesia, respectively. We measured A-lineTM ARX index (AAI), systolic blood pressure, mean arterial pressure, diastolic blood pressure and heart rate at the ward; before the administration of clonidine premedication, before induction, just before intubation and 1 minute after endotracheal intubation, and compared these parameters among the 3 groups.
RESULTS
Each dose of clonidine had a suppressive effect before the induction of anesthesia and suppressed hemodynamics successfully during intubation. In groups 2 and 3, the AAI was lower than in group 1 (P < 0.05), but 7 patients had bradycardia and 3 patients had been hypotensive in group 3.
CONCLUSIONS
Intravenous injection of 2 microgram/kg clonidine as a premedicant reduced AAI significantly (P < 0.05) compared to the control group, with good hemodynamic stability. Therefore, we believe that AAI can be used to predict hypnotic state during propofol anesthesia.
Key Words: alpha2-adrenoreceptor agonist; A-lineTM ARX index (AAI); clonidine


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
(서울특별시 마포구 마포대로 109 롯데캐슬 프레지던트 101동 3503호)
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                
Business Name: Korean Society of Anesthesiologists (대한마취통증의학회)
Business Registration: 106-82-07194
Representative: Young-Tae Jeon (전영태)

Copyright © 2025 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next