Korean J Anesthesiol Search

CLOSE


Korean Journal of Anesthesiology 1999;36(1):4-12.
DOI: https://doi.org/10.4097/kjae.1999.36.1.4   
Low Flow Anesthesia with Continuous Infusion of Liquid Enflurane into Breathing Circuit.
Chan Jong Chung, Jong Kook Lee, Seung Cheol Lee, Young Jhoon Chin
Department of Anesthesiology, College of Medicine, Dong-A University, Pusan, Korea.
Abstract
BACKGROUND
Lowe and Ernst's square root of time model employs direct injection of liquid agent into breathing circuit for low flow anesthesia. Intermittent injections of the agent by Lowe's method change rapidly arterial partial pressure of the agent and fail to maintain hemodynamic stability to surgical stimuli. We designed to investigate the possibility and safety of low flow anesthesia with continuous infusion of liquid enflurane into breathing circuit.
METHODS
Twenty patients, ASA physical status I or II, undergoing gastrectomy under inhalational general anesthesia were randomly divided into two groups. Anesthesia was maintained with a fresh gas flow of O2 500 ml/min and continuous infusion of liquid enflurane. An identical semiclosed Dr ger circle anesthesia system was used to all patients. Liquid enflurane calculated by the Lowe's method (group I) or simplified by patient's weight (group II) was continuously infused directly into inspiratory limb of breathing circuit using syringe pump. Inspiratory and expiratory concentrations of enflurane, enflurane consumptions, hemodynamic parameters, carboxyheomoglobin were checked intraoperatively. Hepatic and renal functions were evaluted postoperatively.
RESULTS
Liquid enfurane was initially infused at a rate in ml/hr of 16.1 0.8 weight in kg in group I and 1.0 weight in kg in group II. After 5 minutes the infusion rate was reduced to 20% of this value and then well adjusted to maintain blood pressure within 20% of the reference preoperative value. Enflurane consumptions and recovery time were similar between the two groups. There were no clinical significant changes in arterial blood gas, carboxyheomoglobin, and hepatic and renal functions.
CONCLUSIONS
These data show that low flow anesthesia with continuous infusion of liquid enflurane into breathing circuit is safe and effective, and that the infusion method simplified by patient's weight may easily be applied to clinical practice for low flow anesthesia.
Key Words: Anesthetics, enflurane; Anesthetic techniques, low flow anesthesia, liquid infusion


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                

Copyright © 2024 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next