Korean J Anesthesiol Search

CLOSE


Korean Journal of Anesthesiology 1997;33(2):330-335.
DOI: https://doi.org/10.4097/kjae.1997.33.2.330   
The Effects of CO2 Insufflation on Jugular Bulb Venous Blood Oxygen Saturation during Thoracoscopy.
Young Cheol Woo, Dong Suep Sohn
Abstract
BACKGROUNDS
Carbon Dioxide (CO2) insufflation during thoracoscopy may result in adverse hemodynamic consequences such as increase in central venous pressure, decrease in cardiac output and increase in arterial carbon dioxide pressure. But the cerebral effects of CO2 insufflation during thoracoscopy are not known yet. To evaluate the cerebral effect of CO2 insufflation during thoracoscopy, jugular bulb venous blood oxygen saturation and pressure were measured.
METHODS
Nine patients were underwent thoracic surgery by thoracoscopy and one lung ventilation. After operation, CO2 was insufflated and hemodynamic parameters, arterial blood pressure, heart rate, central venous pressure, jugular bulb pressure, arterial blood gases and jugular bulb venous blood gases were measured at intrathoracic pressure 5 mmHg, 10 mmHg and 15 mmHg respectively.
RESULTS
Central venous pressure was increased with insufflation of CO2 of 10 mmHg and 15 mmHg. Jugular bulb pressure was increased with insufflationof of CO2 of 5mmHg, 10 mmHg and 15 mmHg. Arterial PCO2, jugular bulb venous PO2 and jugular bulb venous blood oxygen saturation were increased with insufflation of CO2 of 5 mmHg, 10 mmHg and 15 mmHg.
CONCLUSION
CO2 insufflation pressure of 5 mmHg or greater resulted in significant increase in jugular bulb venous blood oxygen saturation and pressure.
Key Words: Monitoring, venous blood gas; Veins, jugular; Ventilation, one-lung, thoracoscopy


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                

Copyright © 2024 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next