Korean Journal of Anesthesiology 1997;33(4):648-652.
DOI: https://doi.org/10.4097/kjae.1997.33.4.648   
The Effects of Tracheal Intubation with McCoy or Macintosh Laryngoscope on Blood Pressure, Heart Rate.
Jin Soo Joo, Youn Suk Lee, Dae Hyun Jo, Hae Kyoung Kim, Choon Kun Chung
Abstract
BACKGROUND
The aim of this study was to compare the cardiovascular changes followed by laryngoscopy with the McCoy laryngoscope blade with those followed by laryngoscopy with the Macintosh laryngoscope blade.
METHODS
Forty eight patients were randomly divided into two groups. Following induction with fentanyl 2 mcg/kg and thiopental 5 mg/kg, and muscle relaxation with vecuronium 0.1 mg/kg, the vocal cords were visualized with either the McCoy or the Macintosh laryngoscope blade, then tracheal intubation was performed. Heart rate and arterial blood pressure were measured just before and after laryngoscopy, and 1, 3 and 5 min later.
RESULTS
There was a significant increase in both heart rate and arterial blood pressure after tracheal intubation using the Macintosh laryngoscope. Also, use of the McCoy blade resulted in a significant increase in both heart rate and arterial blood pressure.
CONCLUSIONS
There was no significant difference on arterial pressure and heart rate to laryngoscopy and tracheal intubation with either the McCoy blade or the Macintosh.
Key Words: Anesthetic technique, intubation; Equipment, laryngoscope


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                

Copyright © 2024 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next