Korean Journal of Anesthesiology 1994;27(9):1164-1168.
DOI: https://doi.org/10.4097/kjae.1994.27.9.1164   
Movement of Double - lumen Endobronchial Tubes During Position Change.
Kwang Ho Lee, Hyun Kyoung Lim, Kyung Bong Yoon, Dae Ja Um, Hyun Kyo Lim
1Department of Anesthesiology, Yonsei University Wonju College of Medicine, Wonju, Korea.
2Department of Anesthesiology, Wonju Military Hospital, Wonju, Korea.
Abstract
Accurate placernent of double-lumen endobronchial tube is essential for successful one lung anesthesia We studied 58 adult patients (38 males and 20 females) undergoing thoracic surgery under one lung anesthesia. We used the fiberoptic bronchoscope as an "introducer" over which the double lumen tube was advanced under direct vision. Correct position of the left side double-lumen endobronchial tube at supine position was determined by direct vision of cephalad surface of the bright blue bronchial cuff immediately below the carina. Correct position of the right side double lumen endobronchial tube at supine position was determined by direct vision of the right upper lobe bronchial orifice through the right upper labe ventilation slot. After the patient was repositioned, the position of the double lumen endobronchial tube was rechecked by fiberoptic bronchoscope. The results were as follows; 1) There was a significant correlation of correct depth of left and right double lumen endobronchial tube at supine position with height for both male and female patients. 2) Left side double lumen endobronchial tube: 58% of total cases (20 Case of 38 Case) were displaced by turning of the patient from supine to the lateral decubitus position. 3) Right side double lumen endobronchial tube: 65% of total cases (13 Case of 20 Case) were displaced by turning of the patient from supine to the lateral decubitus position.
Key Words: Double lumen endobronchial tube; Fiberoptic bronchoscope; One lung anesthesia


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                

Copyright © 2024 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next