Korean J Anesthesiol Search

CLOSE


Previous issues

  • HOME
  • BROWSE ARTICLES
  • Previous issue
Volume 66(4); Apr 2014
Editorial
Could this be another story of montage?
Sung Uk Choi
Korean J Anesthesiol. 2014;66(4):265-266.   Published online April 28, 2014
Clinical Research Articles
Comparison of bispectral index scores from the standard frontal sensor position with those from an alternative mandibular position
Shin Young Lee, Young Sung Kim, Byung Gun Lim, Heezoo Kim, Myoung-Hoon Kong, Il-Ok Lee
Korean J Anesthesiol. 2014;66(4):267-273.   Published online April 28, 2014
Background

The standard bifrontal application of the bispectral index (BIS) sensor interferes with the operative field in neurosurgery and plastic surgery. The aim of this study was to compare the standard frontal BIS sensor position with an alternative position across the mandible.

Methods

Two BIS™ Quatro sensors (Aspect Medical Systems, Newton, MA, USA) mounted on the frontal and mandibular regions were connected to BIS Vista™ monitors on each patient during general anesthesia. Data from each position were collected at awake, loss of consciousness, intubation, incision, every 30 minutes during the intraoperative period and emergence. These data were compared using Bland-Altman and scatter plot analyses.

Results

Scatter plot analysis revealed a significant correlation between BIS values of frontal and mandibular positions (R = 0.869, P = 0.000), except during emergence (R = 0.253, P = 0.077). Bland-Altman analysis revealed a negative bias of 3.2 with a limit of agreement of 16.5/-22.9, in which 3.7% of the values were outside of the limit of agreement. Additional values included -2.9 (14.1/-8.3) while patients were awake, -21.7 (14.9/-58.3) at loss of consciousness, -1.8 (9.0/-12.5) during maintenance, and -1.9 (14.9/-18.8) during emergence.

Conclusions

Overall, BIS values do not agree between the standard frontal position and an alternative mandibular position. However, during the anesthesia maintenance period, the mandibular position can be availably used as an alternative position if the operative field renders the standard frontal position unavailable.

End-tidal concentration of sevoflurane for preventing rocuronium-induced withdrawal of the arm in pediatric patients
Jong Hoon Yeom, Yong Oh Kim, Jae Min Lee, Woo Jae Jeon
Korean J Anesthesiol. 2014;66(4):274-277.   Published online April 28, 2014
Background

During induction of general anesthesia, the intravenous injection of rocuronium is often associated with withdrawal movement of the arm due to pain, and this abrupt withdrawal may result in dislodgement of the venous catheter, injury, or inadequate injection of rocuronium. We performed this study to evaluate the 50 and 95% effective end-tidal concentrations of sevoflurane (ETsev) for preventing rocuronium-induced withdrawal of the arm.

Methods

We conducted a prospective double-blind study in 31 pediatric patients. After free flow of lactated Ringer's IV fluid was confirmed, anesthesia was induced in the patients by using 2.5% thiopental sodium (4 mg/kg) and sevoflurane (4 vol%) with 6 L/min of oxygen. When the target ETsev was reached, preservative-free 1% lidocaine (1.5 mg/kg) was intravenously injected during manual venous occlusion and rocuronium (0.6 mg/kg) was injected after lidocaine injection under free-flow intravenous fluid. A nurse who was an investigator and was blinded to the ETsev injected the rocuronium. The nurse evaluated the response.

Results

Non-withdrawal movement was observed in 5 out of 11 patients with ETsev 3.0 vol% and in 5 out of 6 patients with ETsev 3.5 vol%. By Dixon's up-and-down method, the 50% effective concentration (EC50) of sevoflurane for non-withdrawal movement at rocuronium injection was 3.1 ± 0.4 vol%. A logistic regression curve of the probability of non-withdrawal movements showed that the 50% effective ETsev for abolishing withdrawal movement at rocuronium injection was 2.9 vol% (95% confidence interval [CI] 2.4-3.8 vol%) and the 95% effective ETsev was 4.3 vol% (95% CI 3.6-9.8 vol%).

Conclusions

This study showed that the 50 and 95% effective ETsev that prevent withdrawal movement at rocuronium injection are 2.9 and 4.3 vol%, respectively.

Remifentanil dose for laryngeal mask airway insertion with a single standard dose of propofol during emergency airway management in elderly patients
Junghee Ryu, Ah Young Oh, Ji-Seok Baek, Jin-Hee Kim, Sang-Heon Park, Jae-Mun Noh
Korean J Anesthesiol. 2014;66(4):278-282.   Published online April 28, 2014
Background

This study determined the dose of remifentanil to use during insertion of a Classic™ laryngeal mask airway (LMA, The Laryngeal Mask Co., Nicosia, Cyprus) in elderly patients during emergency airway management when combined with a single dose of propofol.

Methods

Patients aged 65-80 years were enrolled. Anesthesia was induced with propofol 1 mg/kg, and then a blinded dose of remifentanil was infused over 30 s after confirming the patient's loss of consciousness. The dose of remifentanil was determined using Dixon's up-and-down method, starting at 0.5 ?g/kg (a step size of 0.1 ?g/kg). Insertion of the LMA was attempted 60 s after loss of consciousness.

Results

In total, 23 patients were recruited and the mean age ± standard deviation was 72 ± 3 years. The effective dose for successful LMA insertion in 50% of the patients (ED50) was 0.20 ± 0.05 ?g/kg. No patient needed more than 0.3 ?g/kg.

Conclusions

Remifentanil 0.20 ± 0.05 ?g/kg with propofol 1 mg/kg resulted in excellent LMA insertion in 50% of elderly patients without significant hemodynamic changes during emergency airway management.

Comparison of dexmedetomidine and epinephrine as an adjuvant to 1% mepivacaine in brachial plexus block
Jang-Ho Song, Hee Yong Shim, Tong Joo Lee, Jong-Kwon Jung, Young-Deog Cha, Doo Ik Lee, Gun Woo Kim, Jeong Uk Han
Korean J Anesthesiol. 2014;66(4):283-289.   Published online April 28, 2014
Background

Dexmedetomidine extends the duration of nerve block when administered perineurally together with local anesthetics by central and/or peripheral action. In this study, we compared the duration of nerve block between dexmedetomidine and epinephrine as an adjuvant to 1% mepivacaine in infraclavicular brachial plexus block.

Methods

Thirty patients, scheduled for upper limb surgery were assigned randomly to 3 groups of 10 patients each. We performed brachial plexus block using a nerve stimulator. In the control group (group C), patients received 40 ml of 1% mepivacaine. In group E, patients received 40 ml of 1% mepivacaine containing 200 ?g of epinephrine as an adjuvant. In group D, patients received 40 ml of 1% mepivacaine containing 1 ?g/kg of dexmedetomidine as an adjuvant. Sensory block duration, motor block duration, time to sense pain, and onset time were assessed. We also monitored blood pressure, heart rate, oxygen saturation and bispectral index.

Results

In group D and group E, sensory block duration, motor block duration and time to sense first pain were prolonged significantly compared to group C. However, there was no significant difference between group D and group E.

Conclusions

Perineural 1 ?g/kg of dexmedetomidine similarly prolonged nerve block duration compared to 200 ?g of epinephrine, but slowed heart rate. Thus, dexmedetomidine is expected to be a good alternative as an adjuvant to local anesthesia in patients who are cautioned against epinephrine.

Sevoflurane versus propofol for interventional neuroradiology: a comparison of the maintenance and recovery profiles at comparable depths of anesthesia
Eun-Su Choi, Ji Yeon Shin, Ah Young Oh, Hee-Pyoung Park, Jung-Won Hwang, Young Jin Lim, Young-Tae Jeon
Korean J Anesthesiol. 2014;66(4):290-294.   Published online April 28, 2014
Background

Sevoflurane and propofol are used widely for interventional neuroradiology (INR). Using the bispectral index (BIS), we compared the clinical properties of sevoflurane and propofol anesthesia in patients undergoing INR at comparable depths of anesthesia.

Methods

The patients were allocated randomly into two groups. The sevoflurane group received propofol (1.5 mg/kg), alfentanil (5 ?g/kg), and rocuronium (0.6 mg/kg) for induction, and the propofol group was induced with a target effect-site concentration of propofol (4 ?g/ml), alfentanil (5 ?g/kg), and rocuronium (0.6 mg/kg). After intubation, anesthesia was maintained with sevoflurane or propofol with 67% nitrous oxide in 33% oxygen. Sevoflurane and propofol concentrations were titrated to maintain the BIS at 50-60. Phenylephrine or opioid was used to maintain the mean arterial pressure within 20% of the baseline values. The amounts of phenylephrine or alfentanil used, the number of patients showing movement during the procedure, and the recovery times were recorded.

Results

Compared to the propofol group, the sevoflurane group showed faster recovery in spontaneous ventilation, eye opening, extubation, and orientation (4 vs. 7 min, 7 vs. 9 min, 8 vs. 10 min, 10 vs. 14 min, respectively; P < 0.01). In the propofol group, significantly greater amounts phenylephrine were used (P < 0.05), and more patients moved during the procedure (P < 0.05).

Conclusions

The use of sevoflurane in maintaining anesthesia during INR was associated with faster recovery, less patient movement during the procedure, and a more stable hemodynamic response when compared to propofol.

Multidrug-resistant Acinetobacter baumannii infection in intensive care unit patients in a hospital with building construction: is there an association?
Sepideh Kamalbeik, Haleh Talaie, Arezou Mahdavinejad, Abdollah Karimi, Alireza Salimi
Korean J Anesthesiol. 2014;66(4):295-299.   Published online April 28, 2014
Background

Acinetobacter baumannii (A. baumannii) has emerged globally as a significant pathogen in hospitals. It is also present in soil and water. In a previous study, we discovered that the A. baumannii class 2 integron occurred most frequently. Here, we determined whether the A. baumannii class 2 integron is in the soil around our hospital, and if the soil is the cause for increasing numbers of A. baumannii infections in our intensive care unit (ICU) patients.

Methods

This cross-sectional prospective study was conducted in two ICUs at Loghman-Hakim Hospital, Tehran, Iran, from November 2012 to March 2013. Patient, soil, and hospital environment samples were collected. All isolates were identified using standard bacteriologic and biochemical methods. The phenotypes and genotypes were characterized. The standard disc diffusion method was utilized to test antimicrobial susceptibility. Integron identification was performed by multiplex polymerase chain reaction.

Results

A total of 42 A. baumannii clinical strains were isolated, all from patient samples; 65% of the isolated species were classified as class 2 integrons. The strains were 100% resistant to piperacillin, piperacillin-tazobactam, ceftazidime, ceftriaxone, cotrimoxazole, cefepime, ceropenem, and cefotaxime. However, all of the strains were sensitive to polymyxin B. A. baumannii was detected around the lip of one patient.

Conclusions

Further research is necessary to establish a relationship between A. baumannii and soil, (especially in regards to its bioremediation), as well as to determine its importance in nosocomial infections and outbreaks in the ICU.

Experimental Research Article
Arrangements of the intravenous parallel infusions with anti-reflux valves decreasing occlusion alarm delay
Han Bum Joe, Bong-Ki Moon, Yeon-Ju Lee, Sang-Kee Min
Korean J Anesthesiol. 2014;66(4):300-305.   Published online April 28, 2014
Background

The methods of arrangement of combined intravenous parallel infusions using anti-reflux valve (ARV), with and without anti-syphon valve (ASV) that could decrease occlusion alarm delay were investigated.

Methods

Occlusion challenge tests were mainly performed as bench experiments of four kinds of multiple parallel infusions (10 ml/h and 50 ml/h infusions), which were connected at the proximal or distal portion of ARV, with or without ASV. Alarm threshold was set to 1000 mmHg. Occlusion alarm delays and the compliances of the infusion systems were compared among groups.

Results

Without ASV, compared to 10 ml/h infusion alone distal to anti-reflux valve, 50 ml/h infusion distal to anti-reflux valve reduced the mean alarm delay from 416 ± 7 s to 81 ± 3 s (P < 0.001). Compared to 50 ml/h infusion alone, combined 10 ml/h and 50 ml/h infusion distal to ARV prolonged the alarm delay from 81 ± 3 s to 133 ± 6 s (P < 0.001). However, combined infusions distal to ARV with ASV significantly reduced the alarm delay from 133 ± 6 s to 74 ± 5 s (P < 0.001), and also reduced the compliance of the infusion system from 2.31 ± 0.12 to 1.20 ± 0.08 ?l/mmHg (P < 0.001).

Conclusions

The infusion setup of faster infusion rate, lower compliant system using ASV could effectively decrease occlusion alarm delay during multiple intravenous parallel infusions using ARV.

Case Reports
Videothoracoscopic management of a perforated central vein and pleura after ultrasound-guided internal jugular vein cannulation: a case report
Jeong-Eun Kim, Joon-Pyo Jeon, Yongsuk Kim, Su Ah Jeong, Young-Eun Moon
Korean J Anesthesiol. 2014;66(4):306-309.   Published online April 28, 2014

A 23-year-old male underwent a left internal jugular vein catheterization during extended surgery for treatment of multiple fractures due to a traffic accident. Although the catheterization was performed under ultrasound (US) guidance, iatrogenic perforation of the central vein and pleura occurred. The catheter was removed, and the perforated site was addressed under thoracoscopy rather than an open thoracotomy. This case suggests that using US does not completely guarantee a complication-free outcome, and that catheter placement should be carefully confirmed. In addition, this case suggests that thoracoscopy may be an ideal method of resolving a perforation of the central vein and pleura.

Combined use of a McGrath® MAC video laryngoscope and Frova Intubating Introducer in a patient with Pierre Robin syndrome: a case report
Yongsuk Kim, Jeong Eun Kim, Da Hye Jeong, Jaemin Lee
Korean J Anesthesiol. 2014;66(4):310-313.   Published online April 28, 2014

Patients with Pierre Robin syndrome are characterized by micrognathia, retrognathia, glossoptosis, and respiratory obstruction and are prone to have a difficult-to-intubate airway. The McGrath® MAC video laryngoscope provides a better view of the glottis than a Macintosh laryngoscope, but it is not easy to insert an endotracheal tube through the vocal cords because a video laryngoscope has a much greater curvature than that of a conventional direct laryngoscope and an endotracheal tube has a different curvature. The Frova Intubating Introducer is used as a railroad for an endotracheal tube in cases of a difficult airway. We thought that a combination of these two devices would make it easy to insert an endotracheal tube through the vocal cords, as a McGrath® MAC video laryngoscope provides a better glottic view and the Frova Intubating Introducer is a useful device for placing an endotracheal tube through the glottis. We report a successful endotracheal intubation with use of the McGrath® MAC video laryngoscope and Frova Intubating Introducer in a patient with Pierre Robin syndrome.

Echocardiographic detection of left atrial mobile calcium debris of trido valve surgery: a case report
Young Song, Jae-Kwang Shim, Jong-Min Sun, Bora Lee, Young Lan Kwak
Korean J Anesthesiol. 2014;66(4):314-316.   Published online April 28, 2014

Calcification of the cardiac chambers is among the challenges associated with reoperative cardiac surgeries by increasing the risk of systemic embolization. We experienced a case of an unexpected detected mass by intraoperative transesophageal echocardiography during weaning from cardiopulmonary bypass in a patient undergoing trido mitral and tricuspid valve replacement surgery. The surgically removed mass was identified as calcified tissue. This case shows the importance of careful echocardiographic evaluation of the left heart in patients undergoing repeat valve surgery given their greater potential for embolic sources.

Monitored anesthesia care with dexmedetomidine in transfemoral percutaneous trans-catheter aortic valve implantation: two cases report
Hee-Sun Park, Kyung-Mi Kim, Kyoung-Woon Joung, In-Cheol Choi, Ji-Yeon Sim
Korean J Anesthesiol. 2014;66(4):317-321.   Published online April 28, 2014

Percutaneous trans-catheter aortic valve implantation (TAVI) is recommended for inoperable patients with severe aortic stenosis at high risk for conventional aortic valve replacement. Originally, TAVI was mostly performed under general anesthesia. Here we describe two cases of transfemoral TAVI performed under monitored anesthesia care (MAC) with dexmedetomidine. Dexmedetomidine provides sedation, analgesia with minimal respiratory depression. Although MAC during transfemoral TAVI has limitations, such as unexpected patient movement and difficulty in intra-procedural use of transesophageal echocardiography, MAC with dexmedetomidine is feasible with close monitoring, fluoroscopic guidance and the participation of experienced anesthesiologists.

Anesthesia for non-pulmonary surgical intervention following lung transplantation: two cases report
Misook Seo, Wook Jong Kim, In-Cheol Choi
Korean J Anesthesiol. 2014;66(4):322-326.   Published online April 28, 2014

The survival rate after lung transplantation has increased in recent years, leading to an increase in non-pulmonary conditions that require surgical intervention. These post-transplant surgical procedures, however, are associated with high mortality and morbidity rates. Intra-abdominal conditions are the most common reasons for surgical intervention. We describe here two patients who underwent abdominal surgery under general anesthesia following lung transplantation. One patient underwent cholecystectomy due to cholecystitis after heart-lung transplantation, and the other patient had an exploratory laparotomy for duodenal ulcer perforation after double lung transplantation. Depending on the type of transplant intervention, the physiology of the transplanted lung must be considered for general anesthesia. Knowledge of underlying conditions and immunosuppressive therapy following transplantation are important for safe and effective general anesthesia.

Opinion
Effects of palonosetron on prolongation of corrected QT intervals may be less than reliable
Jeounghyuk Lee, Junyong In
Korean J Anesthesiol. 2014;66(4):327-328.   Published online April 28, 2014


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                
Business Name: Korean Society of Anesthesiologists
Business Registration: 106-82-07194
Representative: Young-Tae Jeon

Copyright © 2026 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next