Editorial
Ephedrine and hypothermia- old drug, new use?
Young-Tae Jeon
Korean J Anesthesiol. 2011;60(4):235-236.   Published online April 26, 2011
Clinical Research Articles
The uncalibrated pulse contour cardiac output during off-pump coronary bypass surgery: performance in patients with a low cardiac output status and a reduced left ventricular function
Youn Yi Jo, Jong Wook Song, Young Chul Yoo, Ji Young Park, Jae Kwang Shim, Young Lan Kwak
Korean J Anesthesiol. 2011;60(4):237-243.   Published online April 26, 2011
Background

We compared the continuous cardiac index measured by the FloTrac/Vigileo™ system (FCI) to that measured by a pulmonary artery catheter (CCI) with emphasis on the accuracy of the FCI in patients with a decreased left ventricular ejection fraction (LVEF) and a low cardiac output status during off-pump coronary bypass surgery (OPCAB). We also assessed the influence of several factors affecting the pulse contour, such as the mean arterial pressure (MAP), the systemic vascular resistance index (SVRI) and the use of norepinephrine.

Methods

Fifty patients who were undergoing OPCAB (30 patients with a LVEF ≥ 40%, 20 patients with a LVEF < 40%) were enrolled. The FCI and CCI were measured and we performed a Bland-Altman analysis. Subgroup analyses were done according to the LVEF (< 40%), the CCI (≤ 2.4 L/min/m), the MAP (60-80 mmHg), the SVRI (1,600-2,600 dyne/s/cm5/m2) and the use of norepinephrine.

Results

The FCI was reliable at all the time points of measurement with an overall bias and limit of agreement of -0.07 and 0.67 L/min/m2, respectively, resulting in a percentage error of 26.9%. The percentage errors in the patients with a decreased LVEF and in a low cardiac output status were 28.2% and 22.3%, respectively. However, the percentage error in the 91 data pairs outside the normal range of the SVRI was 40.2%.

Conclusions

The cardiac output measured by the FloTrac/Vigileo™ system was reliable even in patients with a decreased LVEF and in a low cardiac output status during OPCAB. Acceptable agreement was also noted during the period of heart displacement and grafting of the obtuse marginalis branch.

Comparison of the ease of laryngeal mask airway ProSeal insertion and the fiberoptic scoring according to the head position and the presence of a difficult airway
Joo Hyun Jun, Hee Jung Baik, Jong Hak Kim, Youn Jin Kim, Ri-Na Chang
Korean J Anesthesiol. 2011;60(4):244-249.   Published online April 26, 2011
Background

The sniffing position is recommended for conventional laryngeal mask airway (LMA) insertion. However, there has been a high success rate of LMA insertion with the head in the neutral position. The effect of a difficult airway on the ease of LMA insertion is not clear. In this study, we compared the ease of LMA ProSeal™ (PLMA) insertion and the fiberoptic scoring according to the head position and the presence of a difficult airway.

Methods

After obtaining informed consent from the subjects, we enrolled 144 adult patients (age range: 18-65) with an ASA physical status 1 or 2. After evaluation of the airway, all the patients were grouped into the EA (easy airway) group (n = 68) and the DA (difficult airway) group (n = 76). According to the head position, each group was divided into the EA-SE (extension) group (n = 35), the EA-SN (sniffing) group (n = 33), the DA-SE group (n = 39) and the DA-SN group (n = 37). The success rate and insertion time at the first attempt were evaluated. The position of the PLMA was fiberoptically scored from the mask aperture of the airway tube in the original head position. After the head position was changed to the sniffing and neutral positions in the SE and SN group, respectively, the position of PLMA was re-evaluated fiberoptically.

Results

The success rate and insertion time at the first attempt and the fiberoptic score showed no significant difference among the groups. After head position was changed, there were no significant changes in the fiberopitc scores.

Conclusions

A difficult airway and the head position had no influence on the ease of PLMA insertion and the fiberopic score. Therefore, the head position can be selected according to the individual patient's situation.

The effect of ephedrine on intraoperative hypothermia
Youn Yi Jo, Ji Young Kim, Joon-Sik Kim, Youngjun Kwon, Cheung Soo Shin
Korean J Anesthesiol. 2011;60(4):250-254.   Published online April 26, 2011
Background

Prevention of intraoperative hypothermia has become a standard of operative care. Since ephedrine has a thermogenic effect and it is frequently used to treat hypotension during anesthesia, this study was designed to determine the effect of ephedrine on intraoperative hypothermia of patients who are undergoing spine surgery.

Methods

Twenty-four patients were randomly divided to receive an ephedrine (the ephedrine group, n = 12) or normal saline (the control group, n = 12) infusion for 2 h. The esophageal temperature (the core temperature), the index finger temperature (the peripheral temperature) and the hemodynamic variables such as the mean blood pressure and heart rate were measured every 15 minutes after the intubation.

Results

At the end of the study period, the esophageal temperature and hemodynamic variables were significantly decreased in the control group, whereas those in the ephedrine group were stably maintained. The index finger temperature was significantly lower in the ephedrine group compared to that in the control group, suggesting the prevention of core-to-peripheral redistribution of the heat as the cause of temperature maintenance.

Conclusions

An intraoperative infusion of ephedrine minimized the decrease of the core temperature and it stably maintained the hemodynamic variables during spine surgery with the patient under general anesthesia.

A comparison between caudal block versus splash block for postoperative analgesia following inguinal herniorrhaphy in children
Jun Kong Cheon, Cheon Hee Park, Kan Taeck Hwang, Bo Yoon Choi
Korean J Anesthesiol. 2011;60(4):255-259.   Published online April 26, 2011
Background

We wanted to determine the postoperative analgesic efficacy of preincisional caudal epidural block versus instillation (splash block) following inguinal herniorrhaphy in children.

Methods

Thirty children (age range: 1-7 years) who were scheduled to undergo inguinal herniorrhaphy were divided into 2 groups: the caudal block group and the splash block group with 15 children in each group. Tracheal intubation was performed. Fifteen children received caudal block with 1.0 ml/kg of 0.25% ropivacaine (Group 1). Caudal block was performed using the loss of resistance method via the sacral hiatus. Fifteen children in Group 2 received local instillation (splash block) in the surgical site with up to 0.4 ml/kg of 0.25% ropivacaine. The patients were observed for 90 minutes in the postanesthesia care unit and then they were transferred to the ward. The pain scores were taken 4 times. We assessed pain using the Faces pain scores.

Results

There were no significant differences between the groups regarding the pain scores at 10, 30 and 60 minutes upon entering the postanesthesia care unit. The pain scores of Group 1 were slightly lower at the last evaluation point when compared to that of Group 2. One patient in Group 1 required supplemental postoperative intravenous (IV) tramadol, while all the other patients in both groups did not require supplemental IV tramadol. The intraoperative requirement for sevoflurane was decreased in Group 1 as compared to that of Group 2. There were no major complications related to either type of block.

Conclusions

We conclude that a splash block can have a similar analgesic effect as that of a caudal block for the postoperative herniorrhaphy pain of children.

Analysis of expert consultation referrals for anesthesia-related issues (December 2008-July 2010): KSA legislation committee report
Kook Hyun Lee, Tae-Hun An, Jong Ho Choi, Dong Gun Lim, Yeong-Ju Lee, Duk Kyung Kim
Korean J Anesthesiol. 2011;60(4):260-265.   Published online April 26, 2011
Background

Since 2009, database construction of anesthesia-related adverse events has been initiated through the legislation committee of the Korean Society of Anesthesiologists (KSA), based on expert consultation referrals provided by police departments, civil courts, and criminal courts.

Methods

This study was a retrospective descriptive analysis of expert consultation referrals on surgical anesthesia-related cases between December 2008 and July 2010.

Results

During the given period, 46 surgical anesthesia-related cases were referred to the KSA legislation committee for expert consultation. Because six cases were excluded due to insufficient data, 40 cases were included in the final analysis. Of 40 cases, 29 (72.5%) resulted in death. Respiratory events were most common in both surviving/disabled and dead patients (36.4 vs. 51.7%, respectively; P > 0.05). Overall, respiratory depression due to the drugs used for monitored anesthesia care (MAC) was the most common specific mechanism (25%), in which all but one case (profound brain damage) resulted in death. In all of these cases, surgeons or physicians provided MAC without the help of anesthesiologists.

Conclusions

Overall, the most common damaging mechanism was related to respiratory depression due to sedatives or anesthetics used for MAC. Almost all MAC injury cases are believed to be preventable with the use of additional or better monitoring and an effective response to initial physiological derangement. Thus, it is essential to establish practical MAC guidelines and adhere to these guidelines strictly to reduce the occurrence of severe anesthesia-related adverse outcomes.

Experimental Research Articles
Suction conditions for minimizing the production of free hemoglobin during blood salvage using an autotransfusion apparatus
Sang-Bum An, Eun Su Choi, Wonsik Ahn
Korean J Anesthesiol. 2011;60(4):266-271.   Published online April 26, 2011
Background

Three kinds of conditions should be considered to reduce free hemoglobin production using an autologous cell salvage device. They are the negative suction pressure, the size of suction tip, and the air contact during suction. We want to examine which condition is the most important factor to produce free hemoglobin.

Methods

One pack of red blood cell and one pack of fresh frozen plasma with the same blood type were mixed. They were aspirated based on the two suction pressure (-150 mmHg or -300 mmHg), three sizes of suction tips, and the two conditions of air contact, in which the suction tip was located in the surface of blood or in the middle of the blood. Seven ml sized EDTA tube was used to collect 5 ml blood. All the procedure repeated ten times. Free hemoglobin, total hemoglobin, and hematocrit were measured. Hemolysis ratio was calculated with following formula. Hemolysis ratio = (new free hemoglobin production) × (100-hematocrit) / (total hemoglobin).

Results

Free hemoglobin production and hemolysis ratio were increased when the suction tip was positioned in the surface than when it was in the middle of the blood. The pressure of negative suction and three kinds of the suction tips did not influence the production of free hemoglobin nor the hemolysis ratio.

Conclusions

The air contact is the most important factor to reduce hemolysis using autologous cell salvage device. Suction pressure or suction tip diameter have little influence to produce hemolysis.

The diabetes-induced functional and distributional changes of the alpha 1-adrenoceptor of the abdominal aorta and distal mesenteric artery from streptozotocin-induced diabetic rats
Jong-Hwan Lee, Jae-Hyon Bahk, Sang-Hyun Park, Jin Huh
Korean J Anesthesiol. 2011;60(4):272-281.   Published online April 26, 2011
Background

The aim of this study was to evaluate the effect of diabetes on the function and distribution of vascular α1-adrenoceptors in the abdominal aorta and distal mesenteric artery from streptozotocin (STZ)-induced diabetic rats at the level of the α1-adrenoceptor subtypes.

Methods

Diabetes was induced by a single intravenous injection of STZ (60 mg/kg) in 8 week-old male Sprague-Dawley rats (n = 11). Age-matched normal rats (n = 14) were used as a control group. Four weeks after STZ injection, the tilting-induced change of the mean arterial pressure was recorded. The α1-adrenoceptor subtypes mediating the contractions of the distal mesenteric artery and abdominal aorta were investigated using the agonist phenylephrine and subtype-selective antagonists that included prazocin, 5-methylurapidil and BMY 7378. The expressions of the α1-adrenoceptor subtypes of each artery were examined by immunofluorescence staining using the subtype selective antibodies.

Results

The recovery of the mean arterial pressure was delayed after positional change in the diabetic rats. Compared with that of the normal rats, the contractile response to phenylephrine was increased in the abdominal aortas and it was decreased in the distal mesenteric arteries in the diabetic rats. In addition, compared with the normal rats, the fluorescent intensity of all the α1-adrenoceptor subtypes was increased in the abdominal aortas and it was decreased in the mesenteric arteries of the diabetic rats.

Conclusions

Diabetes increased the contractility of the abdominal aorta in response to phenylephrine, yet diabetes decreased that of the mesenteric arteries in the STZ-induced diabetic rats. Those results are mainly based on the overall change of the α1-adrenoceptor, and not on the change of the specific α1-adrenoceptor subtypes.

Case Reports
Bladder perforation during laparoscopy detected by gaseous distention of the urinary bag -A report of two cases-
Jae Hee Woo, Guie Yong Lee, Hee Jung Baik
Korean J Anesthesiol. 2011;60(4):282-284.   Published online April 26, 2011

Bladder perforation during laparoscopy is a recognized, uncommon complication. We present two cases of bladder perforation during laparoscopic gynecologic operations that were detected by gaseous distention of the urinary bag. Bladder perforation occurred through laparoscopic division of adhesion. One bladder perforation was repaired laparoscopically, and the other case was repaired by laparotomy during the same general anesthesia. In this report, we present evidence that monitoring a gas-distended urinary bag during a laparoscopic procedure can help detect intraoperative bladder perforation.

Tracheal laceration during intubation of a double-lumen tube and intraoperative fiberoptic bronchoscopic evaluation through an LMA in the lateral position -A case report-
Joohee Kim, Taewan Lim, Jae-Hyon Bahk
Korean J Anesthesiol. 2011;60(4):285-289.   Published online April 26, 2011

A 76-year-old, 148-cm woman was scheduled for right upper lobectomy. A 32 Fr left-sided double lumen tube was placed using a conventional technique. Despite several attempts under fiberoptic bronchoscope-guidance, we could not locate the double lumen tube properly. We thus decided to proceed with the bronchial tube in the right mainstem bronchus. During surgery, 8-cm-long laceration was noted on the posterolateral side of the trachea. To check the possibility of laceration of the proximal trachea, the double lumen tube was changed to an LMA for use as a conduit for fiberoptic bronchoscopic evaluation in the lateral position. A plain endotracheal tube with the cuff modified and collapsed was re-intubated after evaluation. And then she was transferred to SICU.

Severe hypotension and water intoxication developed after an accidental oxytocin overdose in a morbidly obese patient undergoing cesarean section -A case report-
Jang Hyeok In, Jin Woo Choi, Hong Soo Jung, Jung-Ah Lee, Jin-Deok Joo, Dae-Woo Kim, Yeon Soo Jeon, Ju-Seon Park
Korean J Anesthesiol. 2011;60(4):290-293.   Published online April 26, 2011

We present a 32-year-old, extremely obese, pregnant woman who developed severe hypotension and water intoxication after an accidental injection of large bolus of oxytocin during cesarean section under general anesthesia. The patient was initially thought to have an amniotic fluid embolism because of the abrupt hemodynamic changes developed immediately after fetal delivery and lack of recognition of medication error. It is highly recommended that careful attention should be paid not only to the possibility of hemodynamic deterioration and water intoxication if oxytocin is given rapidly in excessive doses, but to the confirmation of the proper use of the drug before it is injected.

Postanesthetic torsade de pointes in a patient with unrecognized long QT syndrome -A case report-
Jae-Young Lee, Ju-Hyun Lee, Eun-Hye An, Jun-Gol Song, Pyung Hwan Park
Korean J Anesthesiol. 2011;60(4):294-297.   Published online April 26, 2011

Torsade de pointes (TdP) is a devastating form of polymorphic ventricular arrhythmia associated with corrected QT (QTc) interval prolongation. TdP usually terminates spontaneously but frequently recurs and may degenerate to ventricular fibrillation. The present report describes a case of TdP in a patient being transferred to the postanesthetic care unit following an emergency laparoscopic appendectomy. The patient had undergone open heart surgery 1 week before. Retrospective electrocardiogram analysis revealed the patient had QTc and Tpeak-Tend interval prolongation that had gone unrecognized. We believe TdP may have been induced by accentuation of sympathetic nervous system during emergence from general anesthesia.

Occipital nerve stimulation in a patient with an intractable chronic headache -A case report-
Jae Hyuck Shin, Yong Chul Kim, In Ki Jang, Jae-Hun Kim, Soo Young Park, Sang Chul Lee
Korean J Anesthesiol. 2011;60(4):298-301.   Published online April 26, 2011

Occipital nerve stimulation (ONS) is a form of peripheral nerve stimulation used to treat refractory headaches. The trial of ONS was carried with the midline incision C1-2 level, inserted electrical lead subcutaneously to oblique and cephalad direction followed by trajectory of blunt dissection. We used 8 pole electrical lead to cover lesser occipital nerve, greater occipital nerve, third occipital nerve and great auricular nerve. We anchored the lead at the midline insertion site after confirming the stimulation of the patient. And then we looped and tightened the lead loosely, connected the lead and the extension under right supraspinatus muscle region. After 1 week trial period, we performed the permanent implantation of occipital nerve stimulator. We inserted internal pulse generator under a pocket located at right infraclavicular region. The VAS score dropped from 8/10 to 1-2/10. No serious complications were detected during 1 month follow-up.

Letter to the Editor
The stance of Jehovah's Witnesses on the use blood and Hospital Liaison Committee
Jong Hyun Lee, Wonsik Ahn
Korean J Anesthesiol. 2011;60(4):302-302.   Published online April 26, 2011


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                
Business Name: Korean Society of Anesthesiologists
Business Registration: 106-82-07194
Representative: Young-Tae Jeon

Copyright © 2026 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next