Korean J Anesthesiol Search

CLOSE


Previous issues

  • HOME
  • BROWSE ARTICLES
  • Previous issue
Volume 25(1); Feb 1992
Clinical Research Articles
Influence of Changes in Mixed Venous Oxygen Tension(PvO2) by Extracorporeal Membrane Oxygenation(ECMO) on Hypoxic Pulmonary Vasoconstriction.
Duk Hwan Choi, Seong Deok Kim
Korean J Anesthesiol. 1992;25(1):1-24.
Blood flow generally decreases to areas of the lung that become hypoxie, thereby reducing pulmonary shunt and preventing arterial hypoxemia. The mechanism of blood flow reduction in the hypoxic area is believed to be hypoxic pulmonary vasoconstriction(HPV). Over the years, serious attention has been given to the question of whether hypoxia of the airway(alveolar hypoxia) is the only way to elicit pulmonary vasoconstriction. the current consensus favors this traditional view. Even though the usual experiments have succeeded in proving that a large drop in alveolar PO2(PAO2) does elicit pulmonary vasoconstriction, they have not excluded the possibility that a sufficient drop in mixed venous PO(PvO2) may have the same eonsequenee. The purpose of this study is to test the hypothesis that a decrease in PvO2 may elicit hypoxic pulmonary vasoconstriction. For the selective change of PvOwe used venovenous extracorporeal circulation(VVECMO), a technique which had been tested for adequacy in hemodynamics and oxygenation in preliminary studies on 6 mongrel dogs. In eight pentobarbital-anesthetized, mechanically ventilated mongrel dogs, stepwise reductions in oxygen concentration(F1O2,) from 0.21 to 0.15 and 0.10 caused remarkable HPV. The mean pulmonary arterial pressure(MPAP) and the pulmonary vascular resistance(PVR) were increased from 17.3+/-3 mmHg and 185+/-64 dyne sec cm(-5) in normoxia(F1O2=0.21) to 30+/-6 mmHg and 401+/-257 dyne sec cm in severe hypoxia(F1O2=0.10, P(A)O2=30+/-9 mmHg), respectively ; while, in moderate hypoxia(F1OP2=0.15, P(A)O2=53+/-12 mmHg), only the MPAP increased and the increase was from 17.3+/-3 mmHg to 23+/-3 mmHg. The selective increase in PvO2without any change in P(A)O2 by extracorporeal veno-venous bypass from 37+/-6 mmHg and 22+/-4 mmHg to 54+/-8 mmHg and 45+/-5 mnHg in moderate and severe hypoxia, respectively, depressed HPV: decrease in MPAP in moderate hypoxia(MPAP=21+/-4 mmHg) and decrease in MPAP and PVR in severe hypoxia(MPAP=23+/-5 mmHg, PVR=319+/-228 dyne sec * cm(-5)). This study indicates that the mixed venous oxygen tension is an important determinant of the magnitude of hypoxic pulmonary vasoconstriction in diffuse alveolar hypoxia. Moreover, the method used in this study and the result might be useful other pulmonary pathophysiological studies and clinical situations with acute diffuse alveolar hypoxia, such as acute respiratory failure and chronic obstructive pulmonary diseases.
Neuromuscular and Cardiovascular Effects of Pipecuronium Bromide.
Kyung Ho Hwang, Wook Park, Sung Yell Kim
Korean J Anesthesiol. 1992;25(1):25-40.
Pipecuronium bromide is a new biaquaternary steroid-type neuromuscular bloeking agent that is closely similar to pancuronium and vecuronium in chemical structure. The purpose of this study was to evaluate neuromuscular and cardiovascular effects of pipecuronium bromide in patients under enflurane anesthesia in comparison with those of pan- curonium and vecuronium bromide. 35 ASA class I or II adult patients were assigned to one of the following groups; pipecuro- nium 0.08mg/kg(n=15), vecuronium 0.08mg/kg(n=10), and pancuronium 0.1 mg/kg(n=10) as a bolus dose. To investigate cumulative effect of pipecuronium, an additional incremental doses (1 mg) of pipecuronium were given repeatedly to 5 patients in pipecuronium group at every 25% recovery of first twitch height(Ti) of train-of four(TOF) stimulation after administration of in- itial dose. Anesthesia was induced with iv thiopental 5-6 mg/kg and inhalation of 0 (21/min.)-NO(41/ min.)-enflurane(2%), and maintained with O(11/min.)-NA3(21/min.)-enflurane(1-2%). All pa- tients were intubated at 5 minutes after administration of one of these muscle relaxants fol- lowing T> of TOF was depressed more than 95% of control height. Neuromuscular blocking effect was assessed by electromyographic response of hypothenar muscles in response to TOF stimulation of ulnar nerve every 20 seconds at wrist throughout study. Heart rate, systolic and diastolic blood pressures, and mean arterial pressure were noninvasively measured for 20 minutes after adminisf,ration of muscle relaxant. The results obtained were as follows, 1) The onset times from administration of vecuronium, pipecuronium, and paneuronium to 95% depression of T, were 3.4k0.88, 3.8k0.21, and 4.3+/-0.86min. respectively. The onset time of pipecuronium was similar to that of vecuronium but significantly shorter than that of pancur- onium(p<0.05). 2) The duration of action from administration of pipecuronium to 25% reeovery of T was 92.9 +/-15.3min. which was significantly shorter than that of pancuronium(115.2 +/-17.04min., p< 0.05) and longer than that of vecuronium(27.5 +/-5.89 min., p<0.05). 3) Recovery index of pipecuronium was 39.5+7.53min. which was also shorter than that of pancuronium(46.2+/-3.52 min., p < 0.05) and longer than that of vecuronium(13.3+/-1.77 min., p < 0.05). 4) Durations from 10% to 25% recovery of T1 hy additional incremental doses of pipecuronium were not altered significantly by the repeated administration. 5) There were no significant changes on heart rate and blood pressure by 0.08 mg/kg of pipecuronium or vecuronium while heart rate was increased in 21% to 27% for 20 min. after administration of pancuronium. In conclusion, pipecuronium bromide appears to be a useful alternative to pancuronium or vecuronium in relatively long duration of muscular relaxation in patients in whom hemodynamic changes, especially tachycardia, must be avoided.
The Neuromuscular Effects of Isoflurane and Enflurane on the Vecuronium - induced Neuromuscular Blockade.
Ki Young Lee, Yang Sik Shin, Sang Ki Min, Jong Rae Kim, Kwang Won Park
Korean J Anesthesiol. 1992;25(1):41-45.
Enflurane, and isoflurane potentiated for the vecuronium-induced neuromuscular blokade in a study of 30 patients anesthetized with 1.0 or 1.5 MAC enflurane, and isoflurane or ketaminefentanyl. In the patients anesthetized with 1.0 MAC isoflurane or enflurane, 50% nitous oxide was administrated simultaneously. The median effective dose of vecuronium m the ketamine-fentanyl anesthesia patients(34,0+/-1.2 ug/kg) was higher than that in the 1.0 and 1.5 MAC enflurane or isoflurane patients(2l.2+/-3.2 and 19.4+/-2.7, or 17.8+/-4.5 and 20.0+/-5.3 ug/kg, respectively). There is no significant difference in ED 50 and ED 95 between 1.0 and 1.5 MAC with enflurane or isoflurane. The duration in patients with enflurane was longer than that in the other groups. But, there is no difference in recovery indices among all the groups. The authors conclude that enflurane or isoflurane potentiantes the vecuronium-induced neuromuscular blockade comparing with ketamine-fentanyl anesthesia. Enflurane prolongs the duration of vecuronium in contrast to isoflurane. But, there is no significant difference between 1.0 and 1.5 MAC in same anesthetic considered usually as clinical anesthetic depth.
Comparison of Arterial Blood Pressure Measured with an Aid of Non - invasive and Invasive Methods.
Jae Min Shim, Jae Keun Kim, Moo Il Kwon, Dong Soo Kim
Korean J Anesthesiol. 1992;25(1):46-52.
The frequent measurement and recording of arterial blood pressure are fundamental parts of patient monitoring in the intensive care unit and the operating room. Two major categories of techniques for measuring arterial blood pressures, non-invasive(indirect) and invasive (direct) methods are currently available. But many physicians often have an experience to recognize that there are some variances in arterial blood pressure data depending on the measuring techniques or personnels. In view of these points, we carried out this study to examine whether these variances of arterial blood pressures measured by Riva-Rocci cuff and Korotkoff sound method (indirect l), automatic non-invasive method (indirect 2) and arterial cannulation method (direct) and those measured by nurse and student nurse are statistically significant or not in 14 patients. The results were as follows. l) In contrast to statistically non-significant variances of diastolic and mean blood pressures among indirect 1, 2 and direct method measured by nurse, there was significant variance of systolic blood pressures between indirect l and direct method, 120+/-13 torr and 129+/-15 torr, retrospectively (p<0.05), 2) There were no statistically significant variances of systolic, diastolic and mean blood pres- sure between two indirect methods measured by nurse. 3) In contrast to non-significant variances among systolic blood pressure measured with an aid of indirect 1, 2 and direct method by student nurse, diastolic blood pressure by indirect 1, 88+/-l4 torr was significantly elevated as compared with those by indirect 2 and direct method, 79+/-l3 torr and 81+/-13 torr, retrospectively (p<0.05). 4) there was significant variance of mean blood pressures measured by student nurese between indirect 1 and 2 methods, l0113 torr and 94+/-13 torr, retrospectively (p<0.05). 5) there were significant variances between systolic, diastolic and mean blood pressures of 120+/-13 torr, 80+/-13 torr and 93+/-12 torr measured by nurse and those of l28+/-14 torr, 88+/-14 torr and 101+/-13 torr measured by student nurse, retrospectively (p<0.05).
The Effect of Venoarterial Extracorporeal Lung Assist ( ECLA ) Using a Small - sized Membrane Oxygenator in Hypoxic Dogs.
Kook Hyun Lee, Il Yeong Jeong, Yong Cheol Kim, Young Jin Ro, Kwang Woo Kim
Korean J Anesthesiol. 1992;25(1):53-58.
After the heart-lung machine was used for the open heart surgery, it was hypothesized that the extracorporeal circulation might be applicable to the management of acute respiratory failure. The development of silicone membrane minimized the possible physical or chemieal damages to blood perfused into the oxygenator. Extracorporeal lung assist(ECLA) using a membrane oxygenator has been recognized as a therapeutic modality for acute respiratory failure, To simplify and reduce the voulme of the ECLA circuit, a small oxygenator, surface area 0.3 m2, was developed by Kurare Co., Japan. It was composed of non-microporous hollow fibers. We performed venoarterial(VA) ECLA to evaluate the gas transfer of the Kurare oxygenator. The priming volume of the ECLA circuit was about 150 ml. Venous blood was drained via the right external jugular vein. The maximum bypass flow rate was about l060 ml/min. Oxygenated blood was perfused into aortic arch via the right carotid artery. The increase of arterial oxygen tension was about 58 mmHg during VA ECLA. It was confirmed that Kurare oxygenator was adequate for the oxygenation support on hypoxic dogs. We tried this ECLA circuit on a postoperative cardiac patient on May, 20, 1991. After 90 hours VA ECLA, she recovered without any complicatioris.
Effects of Esmolol on Hemodynamic Responses to Laryngoscopy and Tracheal Intubation in Normotensive Patients.
Jung Koo Lee, Jin Mo Kim, Jung Kil Chung, Jae Kyu Cheun
Korean J Anesthesiol. 1992;25(1):59-66.
Laryngoscopy and endotracheal intubation undergoing general anesthesia cause hypertension and tachycardia with concomitant increases in plasma catecholamine concentration. These transient stress responses are greatly exaggerated in patients with hypertension and cardiovascular diseases and can lead to cardiac arrhythmia, pulmonary edema, cardiac failure and cerebral hemorrhage. Therefore, several attempts have been made to attenuate the hypertensive and tachycardiac responses, but none has been satisfactory. This study was made to alleviate the hemodynamic responses to tracheal intubation using ultra-short acting cardioselective beta-blocker, Esmolol. Following get informed consent in ASA physical status 1 and 2, 28 patients were randomly divided into two groups. Group 1(n=16), control group, and group 2(n=12), esmolol treatment group. Patients on alpha or beta-blockers or agonists were excluded from the study. 12 patients received an infusion of 500 mcg/kg/min esmolol loading dose for 3 min before induction with thiopental and 300 mcg/kg/min for maintenance for 6 additional minutes during the endotra- cheal intubation. The control patients, group 1(n=16), received 5% D/W infusion in place of esmolol with infusion pump. The patients received hydroxyzine 1 mg/kg, nalbuphine 0.1 mg/kg, and glycopyrroate 0.2 mg i. m. 60 minutes before anesthesia. Patients were induced with sodium thiopental 4-5 mg/kg until the disappearance of lid-refex. Succinylcholine 1.0 mg/kg i. v. was used to facilitate endotracheal intubation. As soon as relaxation was complete, laryngoscopy was initiated. After the completion of intubation, nitrous oxide/oxygen=2: 2 L/min with 0.5-1.5 % halothane or enflurane was administered. The blood pressure and heart rate were measured using noninvasive automatic blood pressure manometer Accutorr 1A (Datascope) for 30 minutes per l minute. Blood pressure and heart rate were evaluated at 6 key points; 1) baseline, 2) anesthetic induction, 3) tracheal intubation, 4) I minute postintubation, 5) 2 minutes postintu- bation, and 6) 3 minutes postintubation, Data were analyzed with paired t-tests within the groups. P<0.05 was considered significant. Esmolol infusion significantly prevented the increases in heart rate and rate pressure product caused by laryngoscopy and endotracheal intubation. Esmolol also moderated the increases in pressures. Esmolol infusion may offer an important role in patients in whom an increase in heart rate, blood pressure and/or rate pressure product should be avoided during the endotracheal intubation.
A Study on the Best Positive End - expiratory Pressure of Dogs in Acute Respiratory Failure Induced by Oleic Acid.
Kook Hyun Lee, Sang Hwan Do, Ik Hyun Choe, Kwang Woo Kim
Korean J Anesthesiol. 1992;25(1):67-71.
Controlled mechanical ventilation with positive end-expiratory pressure(PEEP) is a widely accepted method for the treatment of acute respiratory failure. But artificial ventilation with large tidal voume, high airway pressure and an inspired oxygen concentration of l00% are necessary for adequate arterial oxygenation in severe acute pulmonary parenchymal failure. It has been suspected that such therapy may cause irreversible pulmonary damage. The extracorporeal respiratory support has been called extracorporeal membrane oxygenation (ECMO), extracorporeal CO, removal(ECCO2R) or extracorporeal lung assist(ECLA). They are prolonged venoarterial(VA) or venovenous(VV) bypass for the refractory hypoxemia which provides the diseased lung with rest. The respiratory rate can be lowered down to about 4~8 rates/min during ECLA. PEEP is known to improve the ventilation perfusion distribution with alveolar recruitment. Low frequency positive pressure ventilation is accompanied by PEEP to keep alveoli open during ECLA. The level of PEEP must be determined adequately because high PEEP may decrease the cardiac output especially during VV ECLA. The experimental model for acute respiratory failure was induced by the intravenous injection of oleic acid 0.07ml/kg on six mongrel dogs(15.8+/-0.7kg). After values of arterial oxygen saturation(SaO2) and end-tidal CO2(E(T)CO2) were stabilized on the monitor, we measured control values of hemodynamic parameters. The stepwise increase of PEEP from 5 cmH2O to 15 cmH2O via 10 cmH2O was followed by the comparison of the respective hemodynamic values at each PEEP with control. Compared with control, PEEP of 5 cmH2O did not cause any changes and PEEP of 15 cmH, decreased cardiac output. At PEEP of 10 cmHO, the cardiac output and oxygen flux was maintained with normoxia. It was concluded that PEEP of 10 cmHO can be applied to clinical VV ECLA.
The Effect of Venovenous Extracorporeal Lung Assist on the Arterial Oxygen Tension in Hypoxic Dogs.
Kook Hyun Lee, Byung Moon Ham, Sung Eun Jung
Korean J Anesthesiol. 1992;25(1):72-77.
Neonatal venoarterial(VA) extracorporeal lung assist(ECLA) drains venous blood from the right atrium via the right internal jugular vein and perfuses oxygenated blood to the aortic arch via the right common carotid artery. Though VA ECLA supports cardiac function, it is not free from neurologic complications due to ligation of the carotid artery. Venovenous(VV) bypass is used early for acute respiratory failure. To reduce the number of veins ligated, a double lumen tube was developed. VV ECLA using the double lumen tube was tried on eight hypoxic dogs at F1O2 0.15. Control values of hemodynamics and blood gases were obtained while the 0.8 m kolobow lung ventilated with nitrogen gas. We measured the same parameters while ventilating the oxygenator with oxygen(ECLA on). Mean arterial pressure and mean pulmonary arterial pressure were decreased significantly during ECLA on. Bypass flow rate was 1042+/-72ml/min and bypass ratio(bypass flow rate cardiac output X100) was 40+/-15%. Arterial oxygen tension was increased from 52+/-14mmHg to 79+/-23mmHg during ECLA on, whose saturation was 94+/-2%. Venous drainage was limited with a double lumen tube, but it can be used clinically for moderate hypoxemia with ease.
The Effects of Metocurine Iodine and Vecuronium Bromide on Intraocular Pressure with the Priming Principle.
Po Sun Kang, Young Seok Choi
Korean J Anesthesiol. 1992;25(1):78-86.
We measured the intraocular pressure changes in forty female patients (aged from 20 to 50) without a history of ocular or cardiovascular disease who were classified physical status 1 and 2, and scheduled for elective surgery. They were divided into 4 groups. Group l (n=10); metocurime 0.03 mg/kg as a priming dose and metocurine 0.27 mg/ kg as a intubating dose. Group 2 (n= 10); vecuronium 0.008 mg/kg as a priming dose and vecuronium 0.072 mg as a intubating dose. Group 3 (n=10); vecuronium 0.008mg/kg as a priming dose and metocurine 0.27 mg/kg as a intubating dose. Group 4 (n=10); metocurine 0.03mg/kg as a priming dose and vecuronium 0.072 mg/kg as a intubating dose. In this study, metocurine and vecuronium were used with the priming principle. We also measured changes in blood pressure, pulse rate and T1% of Train of four stimulation and evaluated the discomfort after the administration of the priming dose and the difficulties of intubation. The results were as follows, 1) Compared with the control value, there was no increse in intraocular pressure following intubation in all four groups and intraocular pressure of 2 and 4 minutes following intubation decreased significantly in all four groups. The greatest decrease was seen in group 3, but it was not significant when compared to the other three groups. 2) While a transient increase in blood pressure was seen in all four groups, the lowest increase was seen in group 3 as compared to the control value. Blood pressure 4 minutes following intubation decreased significantly in grop 3. 3) A significant decrease in the T1% of the Train of four stimuli at one minute after administration of the intubating dose was seen in group 3 compared to the other three groups. 4) Group 3 showed the lowest number of difficult intubation. In conclusion, the combination of vecuronium and metoeurine with the priming principle provide optimal conditions for smooth and rapid intubation with no elevation of intraocular pressure, blood pressure and heart rate changes for ocular surgery.
Changes of Plasma Concentration of Lidocaine Associated with Pediatric Caudal Anesthesia.
Koang In Kim, Kyu Taek Choi, Jae Kyu Cheun
Korean J Anesthesiol. 1992;25(1):87-95.
Caudal anesthesia appears to be a safe and reliable techniuqe for surgical anesthesia as well as an alternative to narcotics for postoperative analgesia for procedures below the umbilicus. The caudal anesthesia might be particularly helpful in infants and children to avoid repetitive injections of narcotics to control postoperative pain. Advantages of caudal anesthesia for pediatric surgery i.e. clearly defined anatomic landmarks, a simplicity of the technique and high success rate have been reported. However, it has not been popular in clinical practice due to several reasons. First of all, small children do not cooperate with technical procedures. Therfore, an additional measure to provide a cooperative state is needed, such as pentothal or ketamine injection, or general anesthesia induced beforehand. Secondly, there is no clear determination or unanimity in anesthetic dosage according to the patient's age or body weight. Lastly, clinical experience and reports have not been enough for clinical practice. The aim of this study was to determine whether commonly accepted dosages used in infants produce blood levels within a safe range. This study was undertaken to measure changes of plasma concentration of lidocaine in patients with pediatric caudal anesthesia, and to check pain and motor scores and analgesic level at the recovery room. The time courses of the plasma concentration were observed in 29 healthty children(0.5-13 yr) to whom were caudally injected with 1% lidocaine mixed 1: 200,000 epinephrine(10 mg/kg). The plasma concentrations were measured by immunofluoresence assay at the intervals of l5, 30, 45, and 60 minutes. The values of plasma concnetration were 1.67+/-0.41, 1.85+/-0.61, 1.73+/-0.46, 1.75+/-0.29mcg/ml(MEAN+/-SD). The peak plasma concentration was 1.85+/-0.61mcg/ml at 30 minutes. However, there no significant differences during the first hour. No data exceeded 5 mcg/ml which is plasma toxic level of lidocaine, nor children had an experience of toxic complications. When the pain and motor scores were checked in the recovery room, most children had no pain and were not ahle to stand but movalble. Sensory levels were checked up to T9 which were suitable for lower abdominal and perineal surgery. These results indicate that the injection of l% lidocaine 10 mg/kg with epinephrine in children is considered to be safe because plasma concentration dose not exceed the toxic levels.
Effect of the Types of Operation or Agieng on Blood Glucose Changes during Halothane Anesthesia.
Sung Woo Choo, Geu Jeung Yang, Chan Jong Chung, Soo Il Lee
Korean J Anesthesiol. 1992;25(1):96-102.
The goal of this study was of what change in blood glucose the operation area and ageing made during halothane anesthesia. Sixty patients who were chosen randomly were divided into 4 operation groups according to operation site, that is, nil, surface, abdomen and thorax. Again, each operation group was fractionated into the young(below 40 year old), the middle (from 4l to 60) and the old(above 61). The blood sampling was done at preinduction for control value, 15 min, 30 min, 45 min and 60 min after induction for nil, and 15 min, 30 min, 45 min and 60 min after incision for operation-received groups. The results were as follows; 1) In nil, the young and the middle increased, but the old decreased in blood glucose. 2) In operation-received groups, there was no significance in blood glucose change among 3 age fractions. 3) The blood glucose change was larger in operation-received groups than in nil, more prominent in abdomen and thorax groups than in surface group. 4) The blood glucose of preinduction had no significance among 4 operation groups.
Clinical Consideration of Anesthetic Management for Otolaryngeal Laser Surgery.
Hee Kyung Lee, Sang Mok Lee, Byung Yon Kwon
Korean J Anesthesiol. 1992;25(1):103-106.
The laser provides the surgeons with several advantages and are capable of providing very high intensity output that can be collimated, resulting in spots sized on the order of the wave length of light, having extremely high energy density, therefore pathological tissues can be removed without blood loss or surrounding tissue edema. There are some problems related to anesthetic management for otolaryngeal laser sugery. One such problem is flamibility of endotracheal tube by the laser light and the difficulties of keeping airway open during the surgery. The anesthesiologist should understasnd the character and the hasards of laser light for both the patients and the others in the operating room. We have clinically analyzed 282 cases of otolaryngeal laser surgery to study their hasards and the anesthetic problems, from January 4th 1988 to December 31,1990. in Wallace Memorial Hospital, Pusan, Korea. The results were as follows 1) Endotracheal tube cuff perforation has occured during otolaryngeal laser sugery in 10.6 percent by the biginner surgeons, and 1.8 percent by expert surgeons. 2) Endotracheal tube firing did not occured by using the endotracheal tube, that was wrapped with aluminum foil tape. 3) Kinking of the endotracheal tube occured frequently by using these tubes during otolaryngeal laser surgery in 5.7 percent by biginner surgeons and 1.4 percent by expert surgeons.
Clinical Evaluation of Hypobaric Spinal Anesthesia for Total Hip Replacement in Lateral Decubitus Position .
Yang Sik Shin, Kyung Suk Chung, Eun Chi Bang, Jae Sun Shim, Jong Rae Kim
Korean J Anesthesiol. 1992;25(1):107-113.
Hypobaric spinal anesthesia for fifty patients(spinal group) undergoing total hip replacement were compared with general anesthesia(general group) in respect to intraoperative blood loss, changes of blood pressures, postoperative analgesics, etc. Furthermore, the technical aspects were evaluated for hypobaric spinal anesthesia in the lateral position when 1% tetracaine in distilled water (epinephrine 1: 200,000) was administered. The lowest blood pressure parameters were significantly lower in the spinal group(29%) than in the general group(22%). The amount of blood loss in the spinal group was less than that in the general group even though there was no difference in blood replacement between groups. The time period before analgesic use longer in the spinal group(4.1 hours)than the general group(2.7 hours). The most common complication in either group was urinary retention(50% in the spinal and 44% in the general) in which urinary catheterization was necessary. In the general group, thirty-six per cent of the patients had mild fever in the first or second postoperative day which were not consistently related to pulmonary complications. For spinal anesthesia, 5 or 6 mg of 1%-tetracaine in distilled water mixed to 1: 200,000 epinephrine was used. The spinal puncture was performed by a 22G needle on the L2-3 or L3-4 in- tervertebral space with lateral aproach in the position of the operation. Injection speed was controlled to 1 ml/sec in all patients. Sensory levels were reached to T7-8 and T9-10 in the non-dependent and dependent side, respectively. Motor funetion on knee and ankle was lost in the non-dependent side, but not in the dependent side. There were some intraoperative complaintments including positional discomfort on hip rest and shoulder bar. However, there was no remarkable problem in hypobaric spinal anesthesia intraoperatively. The results of our study indicate that hypobaric spinal anesthesia in lateral decubitus position is a recommendable anesthetic technique for total hip replacement surgery.
Effects of Fentanyl - Oxygen Anesthesia on Serum Catecholamine during Open Heart Surgery.
Chong Sung Kim, Jae Hyon Bahk, Sang Tae Kim, Yong Chul Kim, Kwang Woo Kim
Korean J Anesthesiol. 1992;25(1):114-120.
Serum epinephrine and norepinephrine concentrations were measured in 7 patients during fentanyl-oxygen anesthesia, who were undergoing elective open heart surgery(single valvular replacement operations) in Seoul National University Hospital. Sampling times and corresponding total fentanyl doses were as follows; 1) after arterial cannulation 2) 5 minutes after intubation(50 ug/kg of B. Wt) 3) 5 minutes after sternotomy(65 ug/ka) 4) after aortic dissection(75 ug/kg) 5) 15 minutes after initiating bypass 6) 60 minutes after initiating bypass [20 ug/kg of fentanyl was added to the priming solution before initiation of Cardio-pulmonary bypass(CP bypass)]. High Performance Liquid Chromatography(HPLC) was used to analyze hormones. Epinephrine concentrations(pg/ml) corresponding to the sampling times were as follows (mean+/-SE); 1) 213+/-59 2) 199+/-62 3) 246+/-83 4) 173+/-35 5) 270+/-70 6) 269+/-70 Norepinephrine concentrations(pg/ml) were as follows(mean+/-SE); 1) 609+/-107 2) 500+/-73 3) 645+/-152 4) 470+/-82 5) 494+/-65 6) 955+/-311 There were no significant hormonal changes except the 6th norepinephrine value. There were no significant hemodynamic changes except blood pressure decrease at the beginning of CP bypass. It is concluded that high dose fentanyl-oxygen anesthesia was limitedly effective to block the stress of open heart surgery, general anesthesia and CP bypass.
Nausea and Vomiting in the Immediate Postanesthetic Peroid.
Byung Moon Ham, Yong Suk Lee
Korean J Anesthesiol. 1992;25(1):121-125.
The postanesthetic nausea and vomiting during the recovery period was regarded as one of the almost inevitable and undesirable sequelae of surgery and anesthesia. With the progress of anesthetic technics and agents the incidence of this complication has been reduced. The analysis of the incidence of postanesthetic nausea and vomiting that occurred in the postanesthetic recovery room was performed on 4239 patients who received general inhalation anesthesia from Nov. 1988 to Apr. 1989 in Seoul National University Hospital. The overall incidences of postanesthetic nausea and vomiting were 0.4% and 0.5% of 4239 patients, respectively. Although the use of isoflurane among anesthetics was followed by slightly lower incidence significant. The incidence was not significantly related to sex, operation site, and the department of surgery. The incidence decreased much more than before, but because nausea and vomiting can produce undesirable complications they should be carefully prevented and treated.
An Analysis on the Open Heart Patients Having Postoperative Respiratory Care - The 6th report.
Yong Lak Kim, Kwang Won Yum, Yong Chul Kim
Korean J Anesthesiol. 1992;25(1):126-131.
An analysis was performed on 251 open heart patients having post-opertive respiratory care in the respiratory intensive care unit of Seoul National University Hospital during l990. The analysis was done according to disease prevalence, sex, age, pump time, duration of mechanical ventilation and mortality rate. 1) The number of cases of acquired heart disease was more than that of congenital heart disease. 2) The most prevalent disease was double valve disease combined with other. 3) The mean age of the total patients was 42.8. The oldest age group was patients who received CABG and the youngest had a ventricular septal defect. 4) The mean pump time was 109.3 minutes and it was longer in the patients with acquired heart disease by about three times than the patients with congenital heart disease. 5) The mean duration of mechanical ventilation was 72.9 hours and it was longer in the patients with acquired heart disease by about 3 times than those with congenital heart disease. 6) The overall mortality rate was 8.0% which was higher rate than that of the 5th reports, and it was higher in the patients with acquired heart disease than with congenital heart disease. The most prevalent cause of death was low cardiac output syndrome. 7) The length of mechanical ventilation and death rate were closely related with pump time.
Clinical Experiences of Balanced Anesthesia with Nalbuphine or Fentanyl in Cesarean Section.
Myoung Ok Kim, Jae Sun Shim, Youn Woo Lee, Yang Sik Shin, Jong Rae Kim
Korean J Anesthesiol. 1992;25(1):132-137.
The effect of fentanyl and nalbuphine used as analgesics in balanced anesthesia were evaluated in 60 full term parturients, ASA physical status class I or II, sheduled for elective cesarean section. They were injected intramusculary with 0.2 mg of glycopyrrolate 30 minutes to one hour prior to the induction of anesthesia. Four mg/kg of thiopental sodium and one mg/kg of succinylcholine were administered intravenously for the induction and endotracheal intubation. Anesthesia was maintained with 66% of nitrous oxide in oxygen until delivery. Following the intravenous injection of 4 mg-vecuronium, controlled ventilation was applied to maintain at PCO1 30 to 40 mmHg. Immediately after clamping of the umbilical cord, 3 ug/kg of fentanyl(F group) or 0.3 mg/kg of nalbuphine(N group) with 5 mg of droperidol were administered. In the F group, the systolic and diastolic blood pressures at three minutes after fentanyl were significantly lower than those during the preinduction period and during recovery room stay. The systolic BP in the preinduction period was significantly higher than those of three minutes after nalbuphine, and the diastolic BP at the preinduction period was also higher than those of three minutes after nalbuphine and during recovery room stay. Heart rates were significantly increased three minutes after nalbuphine than at recovery room. The blood presures and heart rates were not significantly different between the two groups. The time intervals from the end of the operation to the first analgesics were significantly longer in the N group(mean 11.3 hours) in contrast to the F group(mean 6.9 hours). There were a few complications such as nausea, headache, dizziness, somnolence and euphoria. The incidences of awareness was 13.3 and 6.7% in the F and N group, respectively. We concluded that the balanced anesthetic technique using nalbuphine with droperidol nuder the inhalation of 66%-nitrous oxide resulted in a satisfactory anesthesia for cesarean seetion with good postoperative analgesia.
A Statistical Survey of Foreign Body Removal under General Anesthesia.
Hun Cho, Myeong Hoon Kong, Hye Won Lee, Byung Kook Chae, Seong Ho Chang, Jung Soon Shin
Korean J Anesthesiol. 1992;25(1):138-142.
Foreign body accidents in the air and food passages are common problem encountered in the ENT field. Especially the foreign body accidents in the air passage in the children are serious and urgent. They are influenced by mode of living, customs, habits and environment1). We have clinico-statistically analysed 83 cases removal of foreign bodies in air and food passages under general anesthesia from January 1979 to March 1991 in Korea Univer- sity Hospital. The results are as follows: 1) Of the total 83 cases,64 cases(77.1%) were in food passage and 19 cases(22.9%) were in air passage. 2) Peanuts and beans were the most common intruders of air passage(79%). In the food passage coins enjoyed the greatest popularity(31.3%) and bones, Badook stones, and meats follow in order of frequency. 3) In the age distribution, 42.1% of foreign bodies in food passage and 78.9% of foreign bodies in air passage were under 5 years. 4) Of the total numbers of foreign body cases, 61.4% of the patients were male and 38.6 % were female. 5) In duration of lodgement, 44 cases(68.8) of foreign bodies in food passage and 6 cases(31.6%) in air passage were removed within 24 hours. 6) In food passage, 56 cases(87.5%) of all were diagnosed initially by chest P-A but 9 cases(47%) were diagnosed initially in air passage.
Body Core Temperature Change after Pneumatic Tourniquet Release during Inhalation Anesthesia.
Jai Hyun Hwang
Korean J Anesthesiol. 1992;25(1):143-147.
The tourniquet is usually applied for the orthopedic surgeries on the lower extemity to obtain the bloodless surgical field and to reduce blood loss.However, there are various complications such as nerve and tissue damage from compression, hemodynamic changes, and metabolic changes from ischemia after applieation of the tourniquet. Release of the tourniquet with reperfusion of the lower limb results in transient core body temperature change and other important hemodynamic, respiratory, and metabolic changes. I observed the mild core temperature drop following the release of the tourniquet at the surgical procedure of the lower extremity during inhalation anesthesia. The results were as follows ; The mean drop in temperature of 0.5 degree (about 11.9 min ; mean) was observed following the tourniquet release. Compared with the baseline value, the decreases in temperature at 8, 10 and 15 min, were statistically significant. There was significant correlation between the duration of tourniquet application and temperature drop (r= 0.293).
Comparison of the Cerebral Arterio - Venous Oxygen Content Differences ( AVDO2 ) during Isoflurane and Neurolept Anesthesia for Aneurysmal Surgery.
Haa Soo Kim, Young Jae Kim, Ju Yuel Park
Korean J Anesthesiol. 1992;25(1):148-152.
In 30 patients subjected to craniotomy for cerebral aneurysm, the correlation of cerebral blood flow and cerebral metabolism were evaluated by measuring mean arterial pressure (MAP) and cerebral arterio-venous oxygen content differences(AVDO2) during isoflurane and neurolept anesthesia. 15 patients were given 1 MAC isoflurane anesthesia and 15 patients neurolept anesthesia. MAP, AVDO2 and PaCO2 were measured before skin incision, after skin incision, after opening of dura and after closing of dura. The results were as follows: 1) In both groups, significant increases in MAP was observed after skin incision(P<0.05), no significant difference between the two groups was found. 2) In both groups, significant decreases in AVDO2 was observed after skin incision (<0.05), AVDO, values showed insignificant difference. The results indicate that even moderate increases in MAP after skin incision during isoflurane and neurolept anesthesia affect AVDO2 values, suggesting increases in cerebral blood flow. Therefore measures that prevent increase in MAP during incision should be implemented. The study suggests that isoflurane anesthesia is as useful as neurolept anesthesia in terms of AVDO2 to patients undergoing aneurysmal surgery.
Comparison of Maximum Inspiratory Pressure and Train of Four Ratio at Neuromuscular Recovery of Vecuronium after Neuroleptanesthesia.
Young Jae Kim
Korean J Anesthesiol. 1992;25(1):153-157.
In this study, we have assessed correlation between maximum inspiratory pressure(MIP) and train of four(TOF) ratio. During neuroleptanesthesia, vecuronium was administered intravenously to 45 patients under TOF monitoring. MIP and TOF ratio was measured every 5 minutes at recovery from neuromuscular blockade. The results were as follows: 1) During neuromuscular recovery, good correlation existed between MIP and TOF ratio. 2) When TOF ratio was 0.65+/-0.05, MIP was 30.4I+/-4.47cmH,O. 3) When TOF ratio was 0.85+/-0.05, MIP was 52.18+/-4.34 cmH,O. These results were suggested that TOF ratio of above 0.8 was consistent with ability to protect the patient's airway against aspiration and obstruction.
Interscalene Brachial Plexus Black for the Surgery of Shoulder , Clavicle, and upper Arm.
Kyung Suk Chung
Korean J Anesthesiol. 1992;25(1):158-162.
A number of reports about interscalene brachial plexus block for the surgery of shoulder, clavicle, and upper arm have described the advantage, especially to patients with limited shoulder motion and lung disease. This method can be used for short procedures which are bone biopsy, arthroscopy, closed reduction and percutaneous pinning of shoulder. It can also free from pneumothorax and torniquet pain. But other studies have listed Horners syndrome, phrenic block, recurrent laryngeal block, bilateral anesthesia, and spinal or epidural blockade. Thesecomplications can be avoided by careful procedure. Patients receiving interscalene brachial plexus block were randomly assigned to one of two groups according to the suspected operation time and the extent of trauma site. Group 1 received lidocaine 1.33% and group 2, lidocaine 1.33% plus bupivacaine 0.4~0.5%. All local anesthetics were added adrenalin. The blocks were carried out in the method described by Winnie. The agents used were lidocaine 1.33% and lidocaine 1.33% plus bupivacaine 0.4~0.5%. 12 patients have sufficient analgesia of the shoulder, supraclavicular region, and the upper arm, but one patient required 25 ug fentanyl during operation. There are no other complications except Horneris sign of two patients.
Clinical Study on Emergency Operations Performed Traumatically Injured Patients.
Hyung Mi Kim, Young Seok Choi
Korean J Anesthesiol. 1992;25(1):163-171.
Case Reports
Unusual Prolonged Recovery of Succinylcholine - induced Neuromuscular Block Following Neostigmin.
Yang Sik Shin, Mi Yung Choi, Soon Ho Nam, Kwang Won Park
Korean J Anesthesiol. 1992;25(1):172-176.
We report a case of slow recovery of the neuromuscular block induced by succinylcholine (SCC) immediately after administration of neostigmine for the reversal of pancuronium. Left hemithyroidectomy was performed in a 4l kg female patient under general endotracheal inhalation anesthesia with 50%-nitrous oxide and 2.0%-enflurane. Four mg of pancuronium was used for muscular relaxation to facilitate the controlled ventilaion on the anesthesia ventilator. At the end of the operation, one and a half hours from the injection of pancuronium, 10 mg of pyridostigmine was administered to reverse the neuromuscular blockade. Five minutes later, 25 mg of succinylcholine was given for reintubation. Following this event, train-of-four stimuli was applied under the uncalibrated mode with Datex Relaxograph because apnea followed by SCC appeared for more than 30 minutes. Neuromuscular monitoring revealed fade to less than 50% of the T, ratio. The ventilator was applied for the recovery of neuromuscular blockade for one hour. There was no more late complications after transfer to the ward. The literature relating to this iatrogenic complication and phase II block after SCC is reviewed and discussed.
A Case of Removal of Pheochromocytoma with Enflurane and the Variation of Catecholamine in the Blood.
Hee Koo Yoo, Dong Il Kim, Jong Hun Jun, Jae Chul Shim, Kyoung Hun Kim, Dong Ho Lee, Kyo Sang Kim, Jung Kook Suh, Se Ung Chon, Pa Jong Jung
Korean J Anesthesiol. 1992;25(1):177-183.
The Department. of Anesthesiology of Hanyang University had a case of operation for pheo- chromocytoma. For the operation of pheochromocytoma, used to prazosin for preoperative treatment of hypertension and used to enflurane as inhalational anesthetic, treated with sodium nitroprusside for severe elevation of blood pressure during operation, used to vecuronium for neuromuscular blocker. Also we tried to get the knowledge about the variation of catecholamine concentration in blood through operation. As we used to the other drugs with adequate amount of fluid without any other complication in this operation we reported here with other references and our experience of a case of operation for remove of pheochromocytoma.
Does the " Curare Cleft " on the Capnogram always mean that the Patient is in Need of Relaxant?
Seong Ho Chang, Myeong Hoon Kong
Korean J Anesthesiol. ;25(1):184-186.
A fifty-eight years old male patient was given general anesthesia for the clipping of aneurysm on the posterior communicating artery. The respiration of the patient was controlled with Ohmeda 7000 anesthesia ventilator. During the surgery there appeared curare cleft on the capnogram which did not disappear after the administration of neuromuscular blocker, but disappeared after the change of the anesthesia ventilator with another one. After that another curare cleft was made by the transient obstruction of the outlet of the excess patient circuit gas of the new anesthesia ventilator. It may be said that inappropriately functioning pop-off valve of the anesthesia ventilator can be one of the causes of curare cleft on the capnogram.
A Report of Three Cases of Hypercarbia During General Anesthesia.
Young Ho Kang, Hun Cho, Hye Won Lee, Byung Kook Chae, Seong Ho Chang, Jung Soon Shin
Korean J Anesthesiol. 1992;25(1):187-191.
It is common to use semiclosed circle system for general anesthesia because of economy, easy controllability of humidity and temperature, less contamination of operating room with anesthetic gas etc, but in case of malfunction of unidirectional valve, inappropriate absorption of carbon dioxide,leakage or obstruction of circle system the patient may become fatal. During general anesthesia with newly purchased anesthesia machine(Ohmeda Modulus II plus) we experienced three cases of hypercarbia because of malfunction of expiratory valve which could not be easily found due to overlying PEEP valve.


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                
Business Name: Korean Society of Anesthesiologists
Business Registration: 106-82-07194
Representative: Young-Tae Jeon

Copyright © 2026 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next